1-56
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 1 General Troubleshooting
Verify Wiring from the ONS 15310-MA Shelf and DSX Wiring Panel
Figure 1-9 Handheld Receiver Usage Flowchart
Step 2 Connect a patch cord between the DS1 Port or DS3 Port connector on the handheld receiver and the
desired port of the DSX panel.
The following patch cords are available
• DS-3 patch cords
–
75-ohm male BNC connector to male WECo 440A male connector
–
75-ohm male BNC connector to WECo 358 male connector
–
75-ohm male BNC connector to 75-ohm male BNC connector
Power
ON
MENU
ENTER/
ACCEPT
Send
Report
Prior
Report
Change
Setting
Store
Setting
EXIT TEST
DISPLAY
DISPLAY
(shows stored
test result)
Mode:DS1 or DS3
Note: Command flow for 15454
shelf has other menu options.
TEST SETTINGS
MENU
ENTER/
ACCEPT
ENTER/
ACCEPT
EXIT TEST
Test Complete
Automatic Test Mode
Result is stored.
Go to nest port in
sequence.
Push ENTER if
"OK Prompt"
Mode is "ON".
Fail Pass
EIA 232 Report:
Latest/Both
MENU
Shelf Side: A or B
MENU
OK PROMPT: ON/OFF
MENU
Tone: ON/OFF
MENU
BEGIN
TEST
BEGIN
TEST
BEGIN
TEST
Shelf Type (310 or 454)
Manual Test Mode
(DS1 or DS3 port type,
Tone On/Off, OK Prompts,
Shelf Type, are saved from
prior use.)
(Display gives continuous
test result for port.)
New test report is stored.
Last report is retained.
Prior report is flushed.
Push BEGIN TEST
again to skip ahead
to start testing at port
DS1#29 or DS1#57.