2-143
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
Step 3 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1-800-553-2447) in order to report a Service-Affecting (SA)
problem.
2.7.238 SWTOPRI
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: EXT-SREF, NE-SREF
The Synchronization Switch to Primary Reference condition occurs when the ONS 15310-CL or
ONS 15310-MA switches to the primary timing source (reference 1). The system uses three ranked
timing references. The timing references are typically two BITS-level or line-level sources and an
internal reference.
Note SWTOPRI is an informational condition. It does not require troubleshooting.
2.7.239 SWTOSEC
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: EXT-SREF, NE-SREF
The Synchronization Switch to Secondary Reference condition occurs when the ONS 15310-CL or
ONS 15310-MA has switched to a secondary timing source (reference 2).
Clear the SWTOSEC Condition
Step 1 To clear the condition, clear alarms related to failures of the primary source, such as the “SYNCPRI”
alarm on page 2-144.
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.240 SWTOTHIRD
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: EXT-SREF, NE-SREF
The Synchronization Switch to Third Reference condition occurs when the ONS 15310-CL or
ONS 15310-MA has switched to a third timing source (reference 3).