4-16
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 4 Error Messages
WID-2326 Currently, CTC does not support bridge and roll on circuits that
are entirely created by TL1. To continue with bridge and roll in
CTC, the selected circuits must be upgraded.
Is it OK to upgrade the selected circuits and continue the bridge
and roll operation?
Refer to the warning message text.
WID-2327 Currently, CTC does not support bridge and roll on circuits that
are partially created by TL1. To continue with bridge and roll
in CTC, the selected circuits must be upgraded.
Is it OK to upgrade the selected circuits and continue the bridge
and roll operation?
Refer to the warning message text.
EID-2328 An error occurred during the circuit reconfiguration.
{0}
The attempt to reconfigure the specified
circuit has failed.
EID-2329 {0} of {1} circuits could not be successfully created. A few circuits could not be created.
EID-2330 An error occurred during circuit verification. The selected {0}
is invalid!
{1}
The selected item, specified by {0}, is
invalid as per the details, specified in {1}.
EID-2331 Deleting {0} might be service affecting. Deleting the item can affect the service of
CTC.
EID-2332 A validation error occurred in row {0}.
{1} hold-off timer for {2} must be between {3}-10,000 ms, in
steps of 100 ms.
Refer to the error message text.
EID-2333 The SSLIOP port cannot have the same port value as IIOP port.
Please change it and apply again.
Refer to the error message text.
EID-3001 An Ethernet RMON threshold with the same parameters
already exists. Please change one or more of the parameters and
try again.
Change a few parameters in an Ethernet
remote monitoring (RMON) threshold and
try again.
EID-3002 An error occurred while retrieving defaults from the node: {0} There was an error while retrieving the
defaults from the specified node.
EID-3003 The file {0} cannot be loaded. CTC cannot load the specified file.
EID-3004 Properties cannot be loaded from the node. Refer to the error message text.
EID-3005 NE update properties cannot be saved to the file {0}. CTC cannot save the network element (NE)
update values to the specified file.
EID-3006 NE update properties cannot be loaded from the node. Refer to the error message text.
EID-3007 An error occurred while provisioning the {0}. There was a provisioning error for the
specified item.
EID-3008 This is not a valid card. You cannot perform DWDM automatic
node setup (ANS) from the Card view.
Please navigate to the Node view and try
again.
EID-3009 No {0} was selected. Select the specified item, for example,
VLAN, port, slot, etc.
EID-3010 A bidirectional optical link could not be created. Refer to the error message text.
Table 4-1 Error Messages (continued)