Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.258 VCG-DEG
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: VCG
The VCAT Group Degraded alarm is a VCAT group alarm. The condition occurs when one member
circuit carried by the ML-100T-8 Ethernet card is down. This condition is accompanied by the
“OOU-TPT” alarm on page 2-120. It only occurs when a Critical (CR) alarm, such as LOS, causes a
signal loss.
Note For more information about Ethernet cards, refer to the Cisco ONS 15310-CL and Cisco ONS 15310-MA
Ethernet Card Software Feature and Configuration Guide.
Clear the VCG-DEG Condition
Step 1 Look for and clear any Critical (CR) alarms that apply to the errored card or port.
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.259 VCG-DOWN
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: VCG
The VCAT Group Down alarm is a VCAT group alarm. The condition occurs when both member circuits
carried by the ML-100T-8 Ethernet card are down. This condition occurs in conjunction with another
Critical (CR) alarm.
Note For more information about Ethernet cards, refer to the Cisco ONS 15310-CL and Cisco ONS 15310-MA
Ethernet Card Software Feature and Configuration Guide.
Clear the VCG-DOWN Condition
Step 1 Complete the “Clear the VCG-DEG Condition” procedure on page 2-154.
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).