EID-5019 The manual path trace mode for this equipment does not
support an expected string consisting of all null characters.
Please change the expected string or the path trace mode.
The path trace mode does not support
strings that consist of null characters. You
must either change the expected string or
the path trace mode.
EID-5020 Software activation is in progress. Provisioning is not allowed. Refer to the warning message text.
EID-5021 Software activation is in progress. {0} is not allowed. Refer to the error message text.
WID-5022 Warning: Ethergroup circuits are stateless (that is, always in
service).
The current state selection of {0} will be ignored.
Refer to the warning message text.
EID-5023 CTC cannot communicate with the node.
The operation failed.
CTC encountered a network
communication error. Connectivity
between CTC and the NE was disrupted,
either transiently or permanently.
EID-5024 The overhead circuit will not be upgraded. Refer to the error message text.
WID-5025 The path targeted for this switch request is already active. The
switch request can be applied, but traffic will not switch at this
time.
Refer to the warning message text.
EID-5026 An ONS 15600 cannot serve as the primary or secondary node
in a four-fiber {0} circuit. Please change your ring and/or node
selections so that an ONS 15600 is not chosen as the primary or
secondary node in this four-fiber {1} circuit.
Refer to the error message text.
WID-5027 The {0} Edit dialog box for the ring {1} has been closed due to
significant provisioning changes. These changes might only be
transitory, so you can reopen the {0} Edit dialog box to view
the updated state.
Re-open the BLSR/MS-SPRing edit
window to view the updated state of the
ring.
WID-5028 Warning: This operation should only be used to clean up rolls
that are stuck. It might also affect completeness of the circuit.
Is it OK to continue with the deletion?
Refer to the warning message text.
EID-5029 A software downgrade cannot be performed to the selected
version while an SSXC card is inserted in this shelf. Please
follow the steps to replace the SSXC with a CXC card before
continuing the software downgrade.
Refer to the error message text.
EID-5030 A software downgrade cannot be performed at the present time. Try the software downgrade later.
WID-5031 Canceling a software upgrade during a standby TSC clock
acquisition might result in a traffic outage.
Refer to the warning message text.
EID-5032 An error occurred while accepting the load. Refer to the error message text.
EID-5033 The profile could not be loaded.
An error occurred while decoding the characters.
CTC detected an error while decoding
characters and could not load the profile.
EID-5034 The profile could not be loaded.
An error occurred while trying to recognize the file format.
CTC detected an error and could not load
the profile.
EID-5035 The profile could not be loaded.
An error occurred while reading the file.
CTC could not read the file and is therefore
unable to load the profile.
Table 4-1 Error Messages (continued)