EID-5069 A source node cannot be added to either of these lists. Select a node other than the source node to
add to the route.
EID-5070 A destination node cannot be added to either of these lists. Select a node other than the destination
node to add to the route.
EID-5071 This node already belongs to one of these lists. The node is already selected either in
include or exclude list in the OCH circuit.
EID-5072 An OCH-Trail tunnel link was found but without any associated
circuit.
Create an OCH-Trail circuit associated with
the link.
EID-5073 You are creating an unprotected link from a protected port.
Do you want to continue?
Refer to the error message.
EID-5074 Deleting OCH DCN circuits will cause a loss of connectivity to
nodes in the circuit path that do not have other DCN
connections.
Do you want to continue?
Refer to the error message.
EID-5075 The VLAN ID must be a number between 1 and 4093. Enter a number between 1 and 4093.
EID-5076 An error occurred while provisioning the VLAN ID.
The VLAN ID is already present in the current profile
Select a VLAN ID that is not present in the
current profile.
EID-5077 An error occurred while provisioning the VLAN database
profile.
{0}
CTC could not save the VLAN profile to the
file name mentioned.
EID-5078 The VLAN merge is not complete.
You forgot to fill {0} record(s).
Fill in the number of records specified and
then proceed.
EID-5079 An error occurred while validating the provisionable patchcord. Refer to the error message text.
EID-5080 No rolls are available. You cannot delete a roll without selecting a
roll.
EID-5081 An error occurred while tracing the RPR ring:
{0}
The circuit reference is invalid.
EID-5082 {0} does not support:
- Low-order circuits that have both {1}-protected and
{2}-protected spans and that cross a node that does not have
low-order cross-connect capability.
- High-order circuits that carry low-order circuits with the
parameters described above.
Refer to the error message text.
EID-5083 This circuit is not the same size as the existing circuit {0}.
This circuit has size {1} and the existing circuit has size {2}.
During an RPR circuit creation ML card,
the new circuit size and the existing circuit
size must be the same.
EID-5084 The Trunk model could not be found.
{0}
The trunk specified is not found.
EID-5085 The maximum number of VLAN DB profiles is {0}. Refer to the error message.
EID-5086 The circuit roll failed.
You cannot bridge and roll the selected circuit because it has a
monitor circuit.
Refer to the error message.
Table 4-1 Error Messages (continued)
Error/Warning
ID Error/Warning Message Description