Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
Clear the APSIMP Alarm
Step 1 Check the configuration of the other node in the 1+1 protection group. If the far end is not configured
for 1+1 protection, create the group. For procedures, refer to the “Turn Up Node” chapter in the
Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.
Step 2 If the other end of the group is properly configured or the alarm does not clear after you have provisioned
the group correctly, verify that the working ports and protect ports are cabled correctly.
Caution Always use the supplied electrostatic discharge wristband when working with a powered ONS 15310-CL
or ONS 15310-MA system.
Step 3 Ensure that both protect ports are configured for SONET.
Step 4 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1-800-553-2447).
2.7.13 APS-INV-PRIM
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: OCN
The Optimized 1+1 APS Primary Facility condition occurs on OC-N ports in an optimized 1+1
protection system if the incoming primary section header does not indicate whether it is primary or
secondary.
Note APS-INV-PRIM is an informational condition and does not require troubleshooting. If the APS switch
is related to other alarms, troubleshoot these alarms as necessary using the procedures in this chapter.
2.7.14 APSMM
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: OCN
An APS Mode Mismatch failure alarm occurs on OC-3 ports when there is a mismatch of the protection
switching schemes at the two ends of the span, such as being bidirectional at one end and unidirectional
at the other. Each end of a span must be provisioned the same way: bidirectional and bidirectional or
unidirectional and unidirectional.
If one end is provisioned for 1+1 protection switching and the other is provisioned for UPSR switching,
an APSMM alarm occurs on the ONS 15310-CL or ONS 15310-MA that is provisioned for 1+1
protection switching.