4 Module Mode Commands
90 4025561
Rev
Delta Value in dB relative to nominal
below which the input must fall to
switch.
F 1 to 10 in 0.1 steps
HystAmpl Value above which the input must
rise to start the hysteresis timer to
restore the original switch position
(revert in auto).
F 0.5 to 9.5 in 0.1 steps
HystTime Length of time primary power is
above the restore threshold before
switch to primary (revert in auto).
F 0 to 600 in steps of 1 second
Revert Allows switch to revert to primary
after power is restored.
S Auto (1), Manual (0)
PrimInp Selects primary input (auto mode).
S Port_4 (1), Port_3 (0)
DfltSw Selects the normal switch position
(auto mode).
S Bar (1), Cross (0)
Access Rights Required
Read, ReadWrite, or Admin
Examples
*/* MODULE> show control enable
MODID NAME SETTING UNITS
20/05 Enable On (1)
20/06 Enable On (1)
20/07 Enable On (1)
20/09 Enable On (1)
20/13 Enable Off (0)
SUCCESS!
*/* MODULE> show control *serv*
MODID NAME SETTING UNITS
01/07 Service Off (0)
01/08 ServiceA Off (0)
01/08 ServiceB On (1)
SUCCESS!
*/* MODULE>
Related Commands
show module
show monitor
show alarmstate
show alarmparam