A-14
Catalyst 2950 and Catalyst 2955 Switch Command Reference
OL-10102-02
Appendix A Catalyst 2955 Alarm Commands
show alarm settings
show alarm settings
Use the show alarm settings user EXEC command to display all environmental alarm settings on the
switch.
show alarm settings [ | {begin | exclude | include} expression]
Syntax Description
Command Modes User EXEC
Command History
Usage Guidelines Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
do not appear, but the lines that contain Output appear.
Examples This is an example of output from the show alarm settings command. It shows all the switch alarm
settings that are on the switch:
Switch> show alarm settings
Power Supply
Mode Single
Alarm Disabled
Relay MIN
Notifies Disabled
Syslog Disabled
Temperature-Primary
Alarm Enabled
Thresholds MAX: 95C MIN: -20C
Relay MAJ
Notifies Enabled
Syslog Enabled
Temperature-Secondary
Alarm Disabled
Threshold
Relay
Notifies Disabled
Syslog Disabled
| begin (Optional) Display begins with the line that matches the expression.
| exclude (Optional) Display excludes lines that match the expression.
| include (Optional) Display includes lines that match the specified expression.
expression Expression in the output to use as a reference point.
Release Modification
12.1(12c)EA1 This command was introduced.