A-5
Catalyst 2950 and Catalyst 2955 Switch Command Reference
OL-10102-02
Appendix A Catalyst 2955 Alarm Commands
alarm facility temperature
Examples This example shows how to set the secondary temperature with a high threshold value of 45
0
C with
alarms and how to send traps to the minor relay circuitry, to the syslog, and to an SNMP server:
Switch(config)# alarm facility temperature secondary 45
Switch(config)# alarm facility temperature secondary relay minor
Switch(config)# alarm facility temperature secondary syslog
Switch(config)# alarm facility temperature secondary notifies
This example shows how to disable the secondary temperature alarm:
Switch(config)# no alarm facility temperature secondary 45
This example shows how to set the primary temperature alarm with alarms and traps to go to the syslog
and to the major relay circuitry:
Switch(config)# alarm facility temperature primary syslog
Switch(config)# alarm facility temperature primary relay major
Related Commands Command Description
show alarm settings Displays environmental alarm settings and options.
snmp-server enable traps Enables the switch to send SNMP notification for various trap types to
the network management system (NMS).