Cisco WS-C3550-24-FX-SMI - Catalyst 3550 100BASE-FX Switch Instalační příručka Strana 73

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 150
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 72
2-27
Catalyst 3550 Multilayer Switch Hardware Installation Guide
78-11358-03
Chapter 2 Installing and Starting the Switch
Connecting to DC Power
Figure 2-24 Stripping the Ground Wire
Step 3
Slide the open end of the ground lug over the exposed area of the 6-gauge wire.
Step 4 Using a Panduit crimping tool, crimp the ground lug to the 6-gauge wire, as shown
in Figure 2-25.
Figure 2-25 Crimping the Ground Lug
Step 5
Use the two number-10-32 screws to attach the ground lug and wire assembly to
the switch rear panel RPS connector, as shown in Figure 2-26.
Step 6 Using a ratcheting torque screwdriver, torque each ground-lug screw to 15 lbf-in.
(240 ozf-in.)
Insulation
Wire lead
0.5 in. (12.7 mm)
±
0.02 in. (0.5 mm)
60528
60529
Zobrazit stránku 72
1 2 ... 68 69 70 71 72 73 74 75 76 77 78 ... 149 150

Komentáře k této Příručce

Žádné komentáře