Cisco 2970 - Catalyst Switch Specifikace

Procházejte online nebo si stáhněte Specifikace pro Softwarové příručky Cisco 2970 - Catalyst Switch. Cisco 2970 - Catalyst Switch Specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 674
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Corporate Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 526-4100
Catalyst 2970 Switch
Software Configuration Guide
Cisco IOS Release 12.1(19)EA1
October 2003
Customer Order Number: DOC-7815462=
Text Part Number: 78-15462-03
Zobrazit stránku 0
1 2 3 4 5 6 ... 673 674

Shrnutí obsahu

Strany 1 - Software Configuration Guide

Corporate HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706 USAhttp://www.cisco.comTel: 408 526-4000800 553-NETS (6387)Fax:

Strany 2

ContentsxCatalyst 2970 Switch Software Configuration Guide78-15462-03EtherChannel Port Groups 9-4Connecting Interfaces 9-4Using Interface Configurati

Strany 3 - CONTENTS

5-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesPlanning a Switch ClusterFigure 5-1 Discovery Throug

Strany 4

5-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesPlanning a Switch ClusterDiscovery Through Different

Strany 5 - 5 Clustering Switches 5-1

5-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesPlanning a Switch ClusterDiscovery Through Different

Strany 6

5-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesPlanning a Switch ClusterDiscovery of Newly Installe

Strany 7

5-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesPlanning a Switch ClusterHSRP and Standby Cluster C

Strany 8

5-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesPlanning a Switch ClusterVirtual IP AddressesYou ne

Strany 9

5-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesPlanning a Switch Cluster• Each standby-group membe

Strany 10 - 11 Configuring VLANs 11-1

5-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesPlanning a Switch ClusterWhen the previously active

Strany 11 - Contents

5-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesPlanning a Switch ClusterPasswordsYou do not need t

Strany 12 - 12 Configuring VTP 12-1

5-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesCreating a Switch ClusterAccess Modes in CMSIf your

Strany 13 - 15 Configuring MSTP 15-1

ContentsxiCatalyst 2970 Switch Software Configuration Guide78-15462-03Saving VLAN Configuration 11-7Default Ethernet VLAN Configuration 11-7Creating

Strany 14

5-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesCreating a Switch ClusterNote Refer to the release

Strany 15

5-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesCreating a Switch ClusterFrom CMS, there are two wa

Strany 16

5-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesCreating a Switch ClusterFigure 5-9 Using the Topol

Strany 17 - 21 Configuring UDLD 21-1

5-19Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesCreating a Switch Cluster• CC—Cluster command switc

Strany 18 - 23 Configuring RMON 23-1

5-20Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesVerifying a Switch ClusterVerifying a Switch Cluste

Strany 19 - 25 Configuring SNMP 25-1

5-21Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesUsing the CLI to Manage Switch ClustersUsing the CL

Strany 20 - 27 Configuring QoS 27-1

5-22Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesUsing SNMP to Manage Switch Clusterscluster member

Strany 21

CHAPTER 6-1Catalyst 2970 Switch Software Configuration Guide78-15462-036Administering the SwitchThis chapter describes how to perform one-time operati

Strany 22 - 29 Troubleshooting 29-1

6-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the System Time and DateUnderstanding

Strany 23 - A Supported MIBs A-1

6-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the System Time and DateCisco’s implem

Strany 24

ContentsxiiCatalyst 2970 Switch Software Configuration Guide78-15462-03CHAPTER 12 Configuring VTP 12-1Understanding VTP 12-1The VTP Domain 12-2VTP Mo

Strany 25

6-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the System Time and DateConfiguring NT

Strany 26

6-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the System Time and DateConfiguring NT

Strany 27 - Audience

6-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the System Time and DateConfiguring NT

Strany 28 - Conventions

6-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the System Time and DateConfiguring NT

Strany 29 - Obtaining Documentation

6-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the System Time and DateBeginning in p

Strany 30 - Cisco TAC Website

6-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the System Time and DateCreating an Ac

Strany 31 - TAC Case Priority Definitions

6-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the System Time and DateIf the source

Strany 32

6-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the System Time and DateBeginning in

Strany 33 - Overview

6-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the System Time and DateSetting the S

Strany 34 - Features

6-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the System Time and DateConfiguring t

Strany 35 - Management Options

ContentsxiiiCatalyst 2970 Switch Software Configuration Guide78-15462-03CHAPTER 14 Configuring STP 14-1Understanding Spanning-Tree Features 14-1STP O

Strany 36 - Availability Features

6-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the System Time and DateConfiguring S

Strany 37 - Security Features

6-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the System Time and DateBeginning in

Strany 38 - QoS and CoS Features

6-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchConfiguring a System Name and PromptConfigurin

Strany 39 - Monitoring Features

6-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchConfiguring a System Name and PromptConfigurin

Strany 40 - Port parameters

6-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchConfiguring a System Name and PromptDefault DN

Strany 41 - Port-based Traffic

6-19Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchCreating a BannerIf you use the switch IP addr

Strany 42

6-20Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchCreating a BannerConfiguring a Message-of-the-

Strany 43

6-21Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchCreating a BannerConfiguring a Login BannerYou

Strany 44 - Catalyst 3750

6-22Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the MAC Address TableManaging the MAC

Strany 45 - Figure 1-2 Server Aggregation

6-23Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the MAC Address TableMAC Addresses an

Strany 46

ContentsxivCatalyst 2970 Switch Software Configuration Guide78-15462-03Operations Within an MST Region 15-3Operations Between MST Regions 15-4Hop Cou

Strany 47 - Where to Go Next

6-24Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the MAC Address TableBeginning in pri

Strany 48

6-25Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the MAC Address TableBeginning in pri

Strany 49 - Understanding Command Modes

6-26Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the MAC Address TableTo disable the s

Strany 50 - • Display system

6-27Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the MAC Address TableBeginning in pri

Strany 51 - Understanding the Help System

6-28Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the MAC Address TableFor example, if

Strany 52

6-29Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the ARP TableManaging the ARP TableTo

Strany 53 - Using Command History

6-30Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 6 Administering the SwitchManaging the ARP Table

Strany 54 - Using Editing Features

CHAPTER 7-1Catalyst 2970 Switch Software Configuration Guide78-15462-037Configuring Switch-Based AuthenticationThis chapter describes how to configure

Strany 55

7-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationProtecting Access to Privileged

Strany 56

7-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationProtecting Access to Privileged

Strany 57

ContentsxvCatalyst 2970 Switch Software Configuration Guide78-15462-03Configuring Optional Spanning-Tree Features 16-9Default Optional Spanning-Tree

Strany 58 - Accessing the CLI

7-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationProtecting Access to Privileged

Strany 59

7-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationProtecting Access to Privileged

Strany 60

7-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationProtecting Access to Privileged

Strany 61 - Getting Started with CMS

7-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationProtecting Access to Privileged

Strany 62 - Topology View

7-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationProtecting Access to Privileged

Strany 63 - Table 3-1 Toolbar Buttons

7-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationProtecting Access to Privileged

Strany 64 - Online Help

7-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 65 - Configuration Modes

7-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 66 - Privilege Levels

7-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 67 - Configuring CMS

7-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 68 - Browser Plug-In Requirements

ContentsxviCatalyst 2970 Switch Software Configuration Guide78-15462-03Displaying IGMP Snooping Information 18-12Understanding Multicast VLAN Registr

Strany 69 - HTTP Access to CMS

7-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 70 - Displaying CMS

7-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 71

7-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 72 - Figure 3-5 CMS Startup Report

7-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 73

7-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 74

7-19Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 75

7-20Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 76

7-21Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 77

7-22Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 78 - Assigning Switch Information

7-23Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 79 - Default Switch Information

ContentsxviiCatalyst 2970 Switch Software Configuration Guide78-15462-03CHAPTER 20 Configuring CDP 20-1Understanding CDP 20-1Configuring CDP 20-2Defa

Strany 80 - DHCP Client Request Process

7-24Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 81 - Configuring the DHCP Server

7-25Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 82 - Configuring the Relay Device

7-26Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 83 - Obtaining Configuration Files

7-27Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 84 - Example Configuration

7-28Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 85

7-29Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 86

7-30Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 87 - EXEC command:

7-31Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 88 - Default Boot Configuration

7-32Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 89 - Booting Manually

7-33Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 90

ContentsxviiiCatalyst 2970 Switch Software Configuration Guide78-15462-03Creating a Local SPAN Session 22-11Creating a Local SPAN Session and Configu

Strany 91

7-34Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 92

7-35Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationControlling Switch Access with

Strany 93 - • reload in [hh:]mm [text]

7-36Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationConfiguring the Switch for Loca

Strany 94

7-37Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationConfiguring the Switch for Secu

Strany 95 - Clustering Switches

7-38Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationConfiguring the Switch for Secu

Strany 96 - Understanding Switch Clusters

7-39Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationConfiguring the Switch for Secu

Strany 97

7-40Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationConfiguring the Switch for Secu

Strany 98

7-41Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationConfiguring the Switch for Secu

Strany 99 - Discovery Through CDP Hops

7-42Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 7 Configuring Switch-Based AuthenticationConfiguring the Switch for Secu

Strany 100 - Planning a Switch Cluster

CHAPTER 8-1Catalyst 2970 Switch Software Configuration Guide78-15462-038Configuring 802.1X Port-Based AuthenticationThis chapter describes how to conf

Strany 101

ContentsxixCatalyst 2970 Switch Software Configuration Guide78-15462-03CHAPTER 25 Configuring SNMP 25-1Understanding SNMP 25-1SNMP Versions 25-2SNMP

Strany 102

8-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter8 Configuring 802.1X Port-Based AuthenticationUnderstanding 802.1X Port-Ba

Strany 103

8-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 8 Configuring 802.1X Port-Based AuthenticationUnderstanding 802.1X Port-B

Strany 104

8-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter8 Configuring 802.1X Port-Based AuthenticationUnderstanding 802.1X Port-Ba

Strany 105 - Virtual IP Addresses

8-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 8 Configuring 802.1X Port-Based AuthenticationUnderstanding 802.1X Port-B

Strany 106

8-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter8 Configuring 802.1X Port-Based AuthenticationUnderstanding 802.1X Port-Ba

Strany 107 - Host Names

8-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 8 Configuring 802.1X Port-Based AuthenticationUnderstanding 802.1X Port-B

Strany 108 - Passwords

8-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter8 Configuring 802.1X Port-Based AuthenticationUnderstanding 802.1X Port-Ba

Strany 109 - Creating a Switch Cluster

8-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 8 Configuring 802.1X Port-Based AuthenticationConfiguring 802.1X Authenti

Strany 110 - C3750-24TS

8-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter8 Configuring 802.1X Port-Based AuthenticationConfiguring 802.1X Authenti

Strany 111 - 3750G-24T

8-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 8 Configuring 802.1X Port-Based AuthenticationConfiguring 802.1X Authent

Strany 112

THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOM

Strany 113 - • CC—Cluster command switch

ContentsxxCatalyst 2970 Switch Software Configuration Guide78-15462-03IP ACL Configuration Examples 26-17Numbered ACLs 26-18Extended ACLs 26-18Named

Strany 114 - Verifying a Switch Cluster

8-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter8 Configuring 802.1X Port-Based AuthenticationConfiguring 802.1X Authenti

Strany 115

8-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 8 Configuring 802.1X Port-Based AuthenticationConfiguring 802.1X Authent

Strany 116 - SNMP Manager

8-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter8 Configuring 802.1X Port-Based AuthenticationConfiguring 802.1X Authenti

Strany 117 - Administering the Switch

8-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 8 Configuring 802.1X Port-Based AuthenticationConfiguring 802.1X Authent

Strany 118 - • User show commands

8-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter8 Configuring 802.1X Port-Based AuthenticationConfiguring 802.1X Authenti

Strany 119

8-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 8 Configuring 802.1X Port-Based AuthenticationConfiguring 802.1X Authent

Strany 120 - Configuring NTP

8-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter8 Configuring 802.1X Port-Based AuthenticationConfiguring 802.1X Authenti

Strany 121

8-19Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 8 Configuring 802.1X Port-Based AuthenticationDisplaying 802.1X Statisti

Strany 122 - Configuring NTP Associations

8-20Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter8 Configuring 802.1X Port-Based AuthenticationDisplaying 802.1X Statistic

Strany 123

CHAPTER 9-1Catalyst 2970 Switch Software Configuration Guide78-15462-039Configuring Interface CharacteristicsThis chapter defines the types of interfa

Strany 124

ContentsxxiCatalyst 2970 Switch Software Configuration Guide78-15462-03Configuring Standard QoS 27-26Default Standard QoS Configuration 27-27Default

Strany 125

9-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsUnderstanding Interface TypesPort-

Strany 126

9-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsUnderstanding Interface TypesTwo t

Strany 127

9-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsUnderstanding Interface TypesEther

Strany 128 - Setting the System Clock

9-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsUsing Interface Configuration Mode

Strany 129 - Configuring the Time Zone

9-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsUsing Interface Configuration Mode

Strany 130

9-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsUsing Interface Configuration Mode

Strany 131

9-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsUsing Interface Configuration Mode

Strany 132 - Configuring a System Name

9-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsConfiguring Ethernet InterfacesCon

Strany 133 - Understanding DNS

9-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsConfiguring Ethernet InterfacesCo

Strany 134 - Setting Up DNS

9-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsConfiguring Ethernet Interfaces•

Strany 135 - Creating a Banner

ContentsxxiiCatalyst 2970 Switch Software Configuration Guide78-15462-03CHAPTER 28 Configuring EtherChannels 28-1Understanding EtherChannels 28-1Ethe

Strany 136

9-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsConfiguring Ethernet InterfacesCo

Strany 137 - Configuring a Login Banner

9-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsConfiguring Ethernet InterfacesCo

Strany 138 - Building the Address Table

9-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsConfiguring the System MTUAdding

Strany 139 - MAC Addresses and VLANs

9-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsConfiguring the System MTUNote If

Strany 140

9-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsMonitoring and Maintaining the In

Strany 141

9-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsMonitoring and Maintaining the In

Strany 142

9-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 9 Configuring Interface CharacteristicsMonitoring and Maintaining the In

Strany 143

CHAPTER 10-1Catalyst 2970 Switch Software Configuration Guide78-15462-0310Configuring SmartPort MacrosThis chapter describes how to configure and appl

Strany 144

10-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 10 Configuring SmartPort MacrosConfiguring Smart-Port MacrosConfiguring

Strany 145 - Managing the ARP Table

10-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 10 Configuring SmartPort MacrosConfiguring Smart-Port MacrosCreating and

Strany 146

ContentsxxiiiCatalyst 2970 Switch Software Configuration Guide78-15462-03Using Layer 2 Traceroute 29-14Understanding Layer 2 Traceroute 29-14Usage Gu

Strany 147

10-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 10 Configuring SmartPort MacrosDisplaying SmartPort MacrosThis example s

Strany 148

CHAPTER 11-1Catalyst 2970 Switch Software Configuration Guide78-15462-0311Configuring VLANsThis chapter describes how to configure normal-range VLANs

Strany 149

11-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsUnderstanding VLANsFigure 11-1 shows an example of V

Strany 150

11-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsUnderstanding VLANsSupported VLANsThe switch support

Strany 151 - Disabling Password Recovery

11-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring Normal-Range VLANsFor more detailed defi

Strany 152

11-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring Normal-Range VLANsYou can set these para

Strany 153

11-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring Normal-Range VLANsNormal-Range VLAN Conf

Strany 154

11-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring Normal-Range VLANsinformation about comm

Strany 155

11-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring Normal-Range VLANsNote The switch suppor

Strany 156 - Understanding TACACS+

11-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring Normal-Range VLANsBeginning in privilege

Strany 157

ContentsxxivCatalyst 2970 Switch Software Configuration Guide78-15462-03Copying Configuration Files By Using TFTP B-10Preparing to Download or Upload

Strany 158 - TACACS+ Operation

11-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring Normal-Range VLANsBeginning in privileg

Strany 159 - Configuring TACACS+

11-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring Normal-Range VLANsBeginning in privileg

Strany 160

11-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring Extended-Range VLANsTo return an interf

Strany 161

11-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring Extended-Range VLANs• VLAN IDs in the e

Strany 162

11-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsDisplaying VLANsTo delete an extended-range VLAN, u

Strany 163 - Starting TACACS+ Accounting

11-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VLAN TrunksConfiguring VLAN TrunksThese

Strany 164 - Understanding RADIUS

11-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VLAN TrunksTrunk negotiation is managed

Strany 165 - RADIUS Operation

11-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VLAN TrunksThe trunking mode, the trunk

Strany 166 - Configuring RADIUS

11-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VLAN TrunksConfiguring an Ethernet Inte

Strany 167

11-19Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VLAN TrunksConfiguring a Trunk PortBegi

Strany 168

ContentsxxvCatalyst 2970 Switch Software Configuration Guide78-15462-03Interface Commands C-2Unsupported Privileged EXEC Commands C-2Unsupported Glob

Strany 169

11-20Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VLAN TrunksDefining the Allowed VLANs o

Strany 170

11-21Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VLAN TrunksTo return to the default all

Strany 171 - Defining AAA Server Groups

11-22Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VLAN TrunksFor information about 802.1Q

Strany 172

11-23Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VLAN Trunks• VLANs 8 through 10 retain

Strany 173

11-24Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VLAN TrunksLoad Sharing Using STP Path

Strany 174 - Starting RADIUS Accounting

11-25Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VLAN TrunksBeginning in privileged EXEC

Strany 175

11-26Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VMPSConfiguring VMPSThe VLAN Query Prot

Strany 176

11-27Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VMPSDynamic-Access Port VLAN Membership

Strany 177

11-28Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VMPS• 802.1X ports cannot be configured

Strany 178 - Understanding Kerberos

11-29Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VMPSConfiguring Dynamic-Access Ports on

Strany 179

ContentsxxviCatalyst 2970 Switch Software Configuration Guide78-15462-03

Strany 180 - Kerberos Operation

11-30Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VMPSBeginning in privileged EXEC mode,

Strany 181 - Obtaining a TGT from a KDC

11-31Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VMPSThis is an example of output for th

Strany 182 - Authorization

11-32Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 11 Configuring VLANsConfiguring VMPSFigure 11-5 Dynamic Port VLAN Membe

Strany 183

CHAPTER 12-1Catalyst 2970 Switch Software Configuration Guide78-15462-0312Configuring VTPThis chapter describes how to use the VLAN Trunking Protocol

Strany 184 - Understanding SSH

12-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 12 Configuring VTPUnderstanding VTPThis section contains information abo

Strany 185 - Configuring SSH

12-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 12 Configuring VTPUnderstanding VTPVTP ModesYou can configure a supporte

Strany 186 - Configuring the SSH Server

12-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 12 Configuring VTPUnderstanding VTPVTP advertisements distribute this VL

Strany 187

12-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 12 Configuring VTPUnderstanding VTPFigure 12-1 Flooding Traffic without

Strany 188

12-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 12 Configuring VTPConfiguring VTP• Turn off VTP pruning by making all VL

Strany 189

12-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 12 Configuring VTPConfiguring VTPFor detailed information about vtp comm

Strany 190 - Device Roles

xxviiCatalyst 2970 Switch Software Configuration Guide78-15462-03PrefaceAudienceThis guide is for the networking professional managing the Catalyst 2

Strany 191

12-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 12 Configuring VTPConfiguring VTPCaution Do not configure a VTP domain i

Strany 192 - Figure 8-2 Message Exchange

12-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 12 Configuring VTPConfiguring VTPConfiguring a VTP ServerWhen a switch i

Strany 193 - Supported Topologies

12-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 12 Configuring VTPConfiguring VTPWhen you configure a domain name, it c

Strany 194

12-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 12 Configuring VTPConfiguring VTPBeginning in privileged EXEC mode, fol

Strany 195

12-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 12 Configuring VTPConfiguring VTPBeginning in privileged EXEC mode, fol

Strany 196 - Using 802.1X with Guest VLAN

12-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 12 Configuring VTPConfiguring VTPBeginning in privileged EXEC mode, fol

Strany 197

12-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 12 Configuring VTPConfiguring VTPOnly VLANs included in the pruning-eli

Strany 198 - Default 802.1X Configuration

12-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 12 Configuring VTPMonitoring VTPMonitoring VTPYou monitor VTP by displa

Strany 199

12-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 12 Configuring VTPMonitoring VTP

Strany 200

CHAPTER 13-1Catalyst 2970 Switch Software Configuration Guide78-15462-0313Configuring Voice VLANThis chapter describes how to configure the voice VLAN

Strany 201

xxviiiCatalyst 2970 Switch Software Configuration Guide78-15462-03PrefaceConventionsConventionsThis publication uses these conventions to convey inst

Strany 202

13-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 13 Configuring Voice VLANUnderstanding Voice VLANFigure 13-1 Cisco 7960

Strany 203 - Changing the Quiet Period

13-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 13 Configuring Voice VLANConfiguring Voice VLANConfiguring Voice VLANThi

Strany 204

13-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 13 Configuring Voice VLANConfiguring Voice VLAN• Voice VLAN ports can al

Strany 205 - Configuring the Host Mode

13-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 13 Configuring Voice VLANConfiguring Voice VLANTo return the port to its

Strany 206 - Configuring a Guest VLAN

13-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 13 Configuring Voice VLANDisplaying Voice VLANTo return the port to its

Strany 207

CHAPTER 14-1Catalyst 2970 Switch Software Configuration Guide78-15462-0314Configuring STPThis chapter describes how to configure the Spanning Tree Pro

Strany 208

14-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPUnderstanding Spanning-Tree Features• Spanning-Tree In

Strany 209 - Understanding Interface Types

14-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPUnderstanding Spanning-Tree FeaturesSpanning-Tree Topo

Strany 210 - Switch Ports

14-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPUnderstanding Spanning-Tree FeaturesBridge ID, Switch

Strany 211 - Trunk Ports

14-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPUnderstanding Spanning-Tree FeaturesAn interface moves

Strany 212 - Connecting Interfaces

xxixCatalyst 2970 Switch Software Configuration Guide78-15462-03PrefaceRelated PublicationsRelated PublicationsThese documents provide complete infor

Strany 213

14-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPUnderstanding Spanning-Tree Featuresthere is only one

Strany 214

14-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPUnderstanding Spanning-Tree FeaturesDisabled StateA La

Strany 215

14-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPUnderstanding Spanning-Tree FeaturesSpanning Tree and

Strany 216

14-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPUnderstanding Spanning-Tree FeaturesBecause each VLAN

Strany 217

14-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPUnderstanding Spanning-Tree FeaturesSpanning-Tree Int

Strany 218 - Configuration Guidelines

14-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPConfiguring Spanning-Tree FeaturesConfiguring Spannin

Strany 219

14-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPConfiguring Spanning-Tree FeaturesSpanning-Tree Confi

Strany 220

14-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPConfiguring Spanning-Tree FeaturesChanging the Spanni

Strany 221

14-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPConfiguring Spanning-Tree FeaturesDisabling Spanning

Strany 222 - Configuring the System MTU

14-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPConfiguring Spanning-Tree FeaturesNote The root switc

Strany 223

iiiCatalyst 2970 Switch Software Configuration Guide78-15462-03CONTENTSPreface xxviiAudience xxviiPurpose xxviiConventions xxviiiRelated Publications

Strany 224 - Monitoring Interface Status

xxxCatalyst 2970 Switch Software Configuration Guide78-15462-03PrefaceObtaining Technical AssistanceOrdering DocumentationYou can find instructions f

Strany 225

14-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPConfiguring Spanning-Tree FeaturesConfiguring a Secon

Strany 226

14-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPConfiguring Spanning-Tree FeaturesConfiguring Port Pr

Strany 227 - Configuring SmartPort Macros

14-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPConfiguring Spanning-Tree FeaturesTo return to the de

Strany 228 - Configuring Smart-Port Macros

14-19Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPConfiguring Spanning-Tree FeaturesNote The show spann

Strany 229

14-20Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPConfiguring Spanning-Tree FeaturesConfiguring Spannin

Strany 230 - Displaying SmartPort Macros

14-21Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPConfiguring Spanning-Tree FeaturesConfiguring the For

Strany 231 - Configuring VLANs

14-22Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 14 Configuring STPDisplaying the Spanning-Tree StatusDisplaying the Spa

Strany 232 - Understanding VLANs

CHAPTER 15-1Catalyst 2970 Switch Software Configuration Guide78-15462-0315Configuring MSTPThis chapter describes how to configure the Cisco implementa

Strany 233 - VLAN Port Membership Modes

15-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPUnderstanding MSTPUnderstanding MSTPMSTP, which uses

Strany 234

15-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPUnderstanding MSTPIST, CIST, and CSTUnlike PVST+ and

Strany 235 - Token Ring VLANs

xxxiCatalyst 2970 Switch Software Configuration Guide78-15462-03PrefaceObtaining Additional Publications and InformationOpening a TAC CaseThe online

Strany 236

15-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPUnderstanding MSTPOperations Between MST RegionsIf th

Strany 237 - Saving VLAN Configuration

15-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPUnderstanding MSTPHop CountThe IST and MST instances

Strany 238

15-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPUnderstanding RSTPHowever, the switch does not automa

Strany 239

15-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPUnderstanding RSTPIn a stable topology with consisten

Strany 240 - Deleting a VLAN

15-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPUnderstanding RSTPWhen Switch C is connected to Switc

Strany 241

15-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPUnderstanding RSTPFigure 15-3 Sequence of Events Duri

Strany 242 - Default VLAN Configuration

15-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPUnderstanding RSTPThe RSTP does not have a separate

Strany 243

15-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPConfiguring MSTP Features• Propagation—When an RSTP

Strany 244 - Displaying VLANs

15-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPConfiguring MSTP FeaturesDefault MSTP ConfigurationT

Strany 245 - Configuring VLAN Trunks

15-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPConfiguring MSTP Features• All MST boundary ports mu

Strany 246 - Encapsulation Types

xxxiiCatalyst 2970 Switch Software Configuration Guide78-15462-03PrefaceObtaining Additional Publications and Information• Packet magazine is the Cis

Strany 247

15-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPConfiguring MSTP FeaturesTo return to the default MS

Strany 248

15-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPConfiguring MSTP FeaturesIf any root switch for the

Strany 249 - Configuring a Trunk Port

15-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPConfiguring MSTP FeaturesTo return the switch to its

Strany 250

15-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPConfiguring MSTP FeaturesConfiguring Port Priority I

Strany 251

15-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPConfiguring MSTP FeaturesConfiguring Path CostThe MS

Strany 252

15-19Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPConfiguring MSTP FeaturesConfiguring the Switch Prio

Strany 253

15-20Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPConfiguring MSTP FeaturesTo return the switch to its

Strany 254

15-21Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPConfiguring MSTP FeaturesConfiguring the Maximum-Agi

Strany 255

15-22Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPConfiguring MSTP FeaturesSpecifying the Link Type to

Strany 256 - Configuring VMPS

15-23Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPDisplaying the MST Configuration and StatusDisplayin

Strany 257 - VMPS Configuration Guidelines

CHAPTER 1-1Catalyst 2970 Switch Software Configuration Guide78-15462-031OverviewThis chapter provides these topics about the Catalyst 2970 switch soft

Strany 258 - Configuring the VMPS Client

15-24Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 15 Configuring MSTPDisplaying the MST Configuration and Status

Strany 259 - Reconfirming VLAN Memberships

CHAPTER 16-1Catalyst 2970 Switch Software Configuration Guide78-15462-0316Configuring Optional Spanning-Tree FeaturesThis chapter describes how to con

Strany 260 - Monitoring the VMPS

16-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 16 Configuring Optional Spanning-Tree FeaturesUnderstanding Optional Spa

Strany 261 - VMPS Configuration Example

16-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 16 Configuring Optional Spanning-Tree FeaturesUnderstanding Optional Spa

Strany 262

16-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 16 Configuring Optional Spanning-Tree FeaturesUnderstanding Optional Spa

Strany 263 - Configuring VTP

16-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 16 Configuring Optional Spanning-Tree FeaturesUnderstanding Optional Spa

Strany 264 - The VTP Domain

16-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 16 Configuring Optional Spanning-Tree FeaturesUnderstanding Optional Spa

Strany 265 - VTP Advertisements

16-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 16 Configuring Optional Spanning-Tree FeaturesUnderstanding Optional Spa

Strany 266 - VTP Pruning

16-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 16 Configuring Optional Spanning-Tree FeaturesUnderstanding Optional Spa

Strany 267 - Understanding VTP

16-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 16 Configuring Optional Spanning-Tree FeaturesConfiguring Optional Spann

Strany 268

1-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 1 OverviewFeaturesThe Catalyst 2970 switches have these features:• Ease-o

Strany 269 - VTP Configuration Guidelines

16-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 16 Configuring Optional Spanning-Tree FeaturesConfiguring Optional Span

Strany 270 - Configuration Requirements

16-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 16 Configuring Optional Spanning-Tree FeaturesConfiguring Optional Span

Strany 271 - Configuring a VTP Server

16-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 16 Configuring Optional Spanning-Tree FeaturesConfiguring Optional Span

Strany 272 - Configuring a VTP Client

16-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 16 Configuring Optional Spanning-Tree FeaturesConfiguring Optional Span

Strany 273

16-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 16 Configuring Optional Spanning-Tree FeaturesConfiguring Optional Span

Strany 274 - Enabling VTP Version 2

16-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 16 Configuring Optional Spanning-Tree FeaturesConfiguring Optional Span

Strany 275 - Enabling VTP Pruning

16-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 16 Configuring Optional Spanning-Tree FeaturesDisplaying the Spanning-T

Strany 276

CHAPTER 17-1Catalyst 2970 Switch Software Configuration Guide78-15462-0317Configuring DHCP FeaturesThis chapter describes how to configure Dynamic Hos

Strany 277 - Monitoring VTP

17-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter17 Configuring DHCP FeaturesUnderstanding DHCP FeaturesOption-82 Data Ins

Strany 278

17-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 17 Configuring DHCP FeaturesConfiguring DHCP FeaturesConfiguring DHCP Fe

Strany 279 - Configuring Voice VLAN

1-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 1 OverviewFeatures–Automatic discovery of candidate switches and creation

Strany 280 - Cisco IP Phone Data Traffic

17-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter17 Configuring DHCP FeaturesConfiguring DHCP FeaturesEnabling DHCP Snoopi

Strany 281

17-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 17 Configuring DHCP FeaturesDisplaying DHCP InformationDisplaying DHCP I

Strany 282

17-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter17 Configuring DHCP FeaturesDisplaying DHCP Information

Strany 283

CHAPTER 18-1Catalyst 2970 Switch Software Configuration Guide78-15462-0318Configuring IGMP Snooping and MVRThis chapter describes how to configure Int

Strany 284 - Displaying Voice VLAN

18-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRUnderstanding IGMP SnoopingUnderstan

Strany 285 - Configuring STP

18-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRUnderstanding IGMP SnoopingIGMP Vers

Strany 286 - STP Overview

18-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRUnderstanding IGMP SnoopingFigure 18

Strany 287

18-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRUnderstanding IGMP SnoopingFigure 18

Strany 288

18-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRConfiguring IGMP SnoopingImmediate-L

Strany 289 - Blocking State

18-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRConfiguring IGMP SnoopingDefault IGM

Strany 290 - Forwarding State

1-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 1 OverviewFeaturesManageability FeaturesNote The encrypted Secure Shell (

Strany 291 - Disabled State

18-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRConfiguring IGMP SnoopingTo disable

Strany 292

18-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRConfiguring IGMP SnoopingIGMP snoopi

Strany 293

18-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRConfiguring IGMP SnoopingConfigurin

Strany 294 - STP and IEEE 802.1Q Trunks

18-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRConfiguring IGMP SnoopingBeginning

Strany 295

18-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRDisplaying IGMP Snooping Informatio

Strany 296

18-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRUnderstanding Multicast VLAN Regist

Strany 297

18-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRUnderstanding Multicast VLAN Regist

Strany 298 - Configuring the Root Switch

18-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRConfiguring MVRWhen a subscriber ch

Strany 299

18-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRConfiguring MVRDefault MVR Configur

Strany 300

18-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRConfiguring MVRBeginning in privile

Strany 301 - Configuring Port Priority

1-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 1 OverviewFeatures–Rapid PVST+ for balancing load across VLANs and provid

Strany 302 - Configuring Path Cost

18-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRConfiguring MVRConfiguring MVR Inte

Strany 303

18-19Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRDisplaying MVR InformationThis exam

Strany 304 - Configuring the Hello Time

18-20Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRConfiguring IGMP Filtering and Thro

Strany 305

18-21Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRConfiguring IGMP Filtering and Thro

Strany 306

18-22Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRConfiguring IGMP Filtering and Thro

Strany 307 - Configuring MSTP

18-23Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRConfiguring IGMP Filtering and Thro

Strany 308 - Understanding MSTP

18-24Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRConfiguring IGMP Filtering and Thro

Strany 309 - IST, CIST, and CST

18-25Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRDisplaying IGMP Filtering and Throt

Strany 310

18-26Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 18 Configuring IGMP Snooping and MVRDisplaying IGMP Filtering and Throt

Strany 311 - Boundary Ports

CHAPTER 19-1Catalyst 2970 Switch Software Configuration Guide78-15462-0319Configuring Port-Based Traffic ControlThis chapter describes how to configur

Strany 312 - Understanding RSTP

1-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 1 OverviewFeatures• Multilevel security for a choice of security level, n

Strany 313 - Rapid Convergence

19-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 19 Configuring Port-Based Traffic ControlConfiguring Storm ControlUnders

Strany 314 - Synchronization of Port Roles

19-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 19 Configuring Port-Based Traffic ControlConfiguring Storm ControlNote B

Strany 315 - Table 15-2 RSTP BPDU Flags

19-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 19 Configuring Port-Based Traffic ControlConfiguring Storm ControlTo dis

Strany 316 - Topology Changes

19-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 19 Configuring Port-Based Traffic ControlConfiguring Protected PortsConf

Strany 317 - Configuring MSTP Features

19-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 19 Configuring Port-Based Traffic ControlConfiguring Port BlockingThis e

Strany 318 - MSTP Configuration Guidelines

19-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 19 Configuring Port-Based Traffic ControlConfiguring Port SecuritySwitch

Strany 319

19-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 19 Configuring Port-Based Traffic ControlConfiguring Port Security• Stic

Strany 320

19-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 19 Configuring Port-Based Traffic ControlConfiguring Port Securityof thi

Strany 321

19-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 19 Configuring Port-Based Traffic ControlConfiguring Port Security• You

Strany 322

19-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 19 Configuring Port-Based Traffic ControlConfiguring Port SecurityStep

Strany 323

1-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 1 OverviewFeatures–Trusted boundary for detecting the presence of a Cisco

Strany 324

19-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 19 Configuring Port-Based Traffic ControlConfiguring Port SecurityTo re

Strany 325

19-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 19 Configuring Port-Based Traffic ControlConfiguring Port SecurityThis

Strany 326

19-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 19 Configuring Port-Based Traffic ControlConfiguring Port SecurityTo di

Strany 327

19-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 19 Configuring Port-Based Traffic ControlDisplaying Port-Based Traffic

Strany 328

19-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 19 Configuring Port-Based Traffic ControlDisplaying Port-Based Traffic

Strany 329

CHAPTER 20-1Catalyst 2970 Switch Software Configuration Guide78-15462-0320Configuring CDPThis chapter describes how to configure Cisco Discovery Proto

Strany 330

20-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 20 Configuring CDPConfiguring CDPConfiguring CDPThese sections include C

Strany 331

20-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 20 Configuring CDPConfiguring CDPUse the no form of the CDP commands to

Strany 332 - Understanding Port Fast

20-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 20 Configuring CDPConfiguring CDPBeginning in privileged EXEC mode, foll

Strany 333 - Understanding BPDU Filtering

20-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 20 Configuring CDPMonitoring and Maintaining CDPMonitoring and Maintaini

Strany 334 - Understanding UplinkFast

ContentsivCatalyst 2970 Switch Software Configuration Guide78-15462-03Using Command History 2-5Changing the Command History Buffer Size 2-5Recalling

Strany 335 - Understanding BackboneFast

1-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 1 OverviewDefault Settings After Initial Switch ConfigurationDefault Sett

Strany 336

20-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 20 Configuring CDPMonitoring and Maintaining CDP

Strany 337 - Understanding Root Guard

CHAPTER 21-1Catalyst 2970 Switch Software Configuration Guide78-15462-0321Configuring UDLDThis chapter describes how to configure the UniDirectional L

Strany 338 - Understanding Loop Guard

21-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 21 Configuring UDLDUnderstanding UDLDA unidirectional link occurs whenev

Strany 339

21-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 21 Configuring UDLDUnderstanding UDLD• Event-driven detection and echoin

Strany 340 - Enabling Port Fast

21-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 21 Configuring UDLDConfiguring UDLDConfiguring UDLDThis section describe

Strany 341 - Enabling BPDU Guard

21-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 21 Configuring UDLDConfiguring UDLDEnabling UDLD GloballyBeginning in pr

Strany 342 - Enabling BPDU Filtering

21-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 21 Configuring UDLDDisplaying UDLD StatusResetting an Interface Disabled

Strany 343 - Enabling BackboneFast

CHAPTER 22-1Catalyst 2970 Switch Software Configuration Guide78-15462-0322Configuring SPAN and RSPANThis chapter describes how to configure Switched P

Strany 344 - Enabling Root Guard

22-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANUnderstanding SPAN and RSPANThis section in

Strany 345 - Enabling Loop Guard

22-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANUnderstanding SPAN and RSPANFigure 22-2 Exa

Strany 346

1-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 1 OverviewDefault Settings After Initial Switch ConfigurationMSTP Disable

Strany 347 - Configuring DHCP Features

22-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANUnderstanding SPAN and RSPANAn RSPAN source

Strany 348 - Option-82 Data Insertion

22-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANUnderstanding SPAN and RSPAN• Transmit (Tx)

Strany 349

22-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANUnderstanding SPAN and RSPAN• It can be an

Strany 350

22-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANUnderstanding SPAN and RSPANDestination Por

Strany 351 - Displaying DHCP Information

22-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANUnderstanding SPAN and RSPANRSPAN VLANThe R

Strany 352

22-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANConfiguring SPAN and RSPANIf a physical por

Strany 353

22-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANConfiguring SPAN and RSPANConfiguring Loca

Strany 354 - Understanding IGMP Snooping

22-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANConfiguring SPAN and RSPANCreating a Local

Strany 355 - Joining a Multicast Group

22-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANConfiguring SPAN and RSPANTo delete a SPAN

Strany 356

22-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANConfiguring SPAN and RSPANThe monitoring o

Strany 357 - Leaving a Multicast Group

1-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 1 OverviewNetwork Configuration ExamplesNetwork Configuration ExamplesTh

Strany 358 - Configuring IGMP Snooping

22-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANConfiguring SPAN and RSPANTo delete a SPAN

Strany 359

22-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANConfiguring SPAN and RSPANSpecifying VLANs

Strany 360 - Setting the Snooping Method

22-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANConfiguring SPAN and RSPANThis example sho

Strany 361

22-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANConfiguring SPAN and RSPAN• We recommend t

Strany 362

22-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANConfiguring SPAN and RSPANCreating an RSPA

Strany 363

22-19Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANConfiguring SPAN and RSPANTo remove a sour

Strany 364

22-20Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANConfiguring SPAN and RSPANTo delete a SPAN

Strany 365

22-21Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANConfiguring SPAN and RSPANTo delete an RSP

Strany 366

22-22Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANConfiguring SPAN and RSPANSpecifying VLANs

Strany 367 - Configuring MVR

22-23Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANDisplaying SPAN and RSPAN StatusDisplaying

Strany 368 - Default MVR Configuration

1-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 1 OverviewNetwork Configuration ExamplesBandwidth alone is not the only

Strany 369

22-24Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 22 Configuring SPAN and RSPANDisplaying SPAN and RSPAN StatusThis is an

Strany 370 - Configuring MVR Interfaces

CHAPTER 23-1Catalyst 2970 Switch Software Configuration Guide78-15462-0323Configuring RMONThis chapter describes how to configure Remote Network Monit

Strany 371 - Displaying MVR Information

23-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 23 Configuring RMONConfiguring RMONFigure 23-1 Remote Monitoring Example

Strany 372

23-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 23 Configuring RMONConfiguring RMONDefault RMON ConfigurationRMON is dis

Strany 373 - Configuring IGMP Profiles

23-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 23 Configuring RMONConfiguring RMONTo disable an alarm, use the no rmon

Strany 374 - Applying IGMP Profiles

23-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 23 Configuring RMONConfiguring RMONCollecting Group History Statistics o

Strany 375

23-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 23 Configuring RMONDisplaying RMON StatusCollecting Group Ethernet Stati

Strany 376

CHAPTER 24-1Catalyst 2970 Switch Software Configuration Guide78-15462-0324Configuring System Message LoggingThis chapter describes how to configure sy

Strany 377

24-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 24 Configuring System Message LoggingConfiguring System Message LoggingC

Strany 378

24-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 24 Configuring System Message LoggingConfiguring System Message LoggingT

Strany 379 - Configuring Storm Control

1-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 1 OverviewNetwork Configuration ExamplesFigure 1-1 High-Performance Work

Strany 380 - Understanding Storm Control

24-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 24 Configuring System Message LoggingConfiguring System Message LoggingD

Strany 381 - Enabling Storm Control

24-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 24 Configuring System Message LoggingConfiguring System Message LoggingT

Strany 382

24-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 24 Configuring System Message LoggingConfiguring System Message Loggingi

Strany 383 - Configuring Protected Ports

24-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 24 Configuring System Message LoggingConfiguring System Message LoggingE

Strany 384 - Configuring Port Blocking

24-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 24 Configuring System Message LoggingConfiguring System Message LoggingT

Strany 385 - Configuring Port Security

24-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 24 Configuring System Message LoggingConfiguring System Message LoggingT

Strany 386 - Security Violations

24-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 24 Configuring System Message LoggingConfiguring System Message Logging

Strany 387

24-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 24 Configuring System Message LoggingConfiguring System Message Logging

Strany 388

24-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 24 Configuring System Message LoggingDisplaying the Logging Configurati

Strany 389

CHAPTER 25-1Catalyst 2970 Switch Software Configuration Guide78-15462-0325Configuring SNMPThis chapter describes how to configure the Simple Network M

Strany 390

1-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 1 OverviewNetwork Configuration Examples• Server aggregation (Figure 1-2

Strany 391

25-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 25 Configuring SNMPUnderstanding SNMPThis section includes information a

Strany 392

25-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 25 Configuring SNMPUnderstanding SNMPTable 25-1 identifies the character

Strany 393

25-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 25 Configuring SNMPUnderstanding SNMPSNMP Agent FunctionsThe SNMP agent

Strany 394

25-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 25 Configuring SNMPUnderstanding SNMPUsing SNMP to Access MIB Variables

Strany 395 - Configuring CDP

25-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 25 Configuring SNMPConfiguring SNMPSNMP ifIndex MIB Object ValuesIn an N

Strany 396

25-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 25 Configuring SNMPConfiguring SNMPDefault SNMP ConfigurationTable 25-4

Strany 397 - Disabling and Enabling CDP

25-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 25 Configuring SNMPConfiguring SNMPDisabling the SNMP AgentBeginning in

Strany 398

25-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 25 Configuring SNMPConfiguring SNMPNote To disable access for an SNMP co

Strany 399

25-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 25 Configuring SNMPConfiguring SNMPBeginning in privileged EXEC mode, f

Strany 400

25-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 25 Configuring SNMPConfiguring SNMPConfiguring SNMP NotificationsA trap

Strany 401 - Configuring UDLD

1-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 1 OverviewNetwork Configuration ExamplesSmall to Medium-Sized Network Us

Strany 402 - Understanding UDLD

25-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 25 Configuring SNMPConfiguring SNMPNote Though visible in the command-l

Strany 403

25-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 25 Configuring SNMPConfiguring SNMPBeginning in privileged EXEC mode, f

Strany 404

25-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 25 Configuring SNMPConfiguring SNMPThe snmp-server host command specifi

Strany 405 - Enabling UDLD on an Interface

25-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 25 Configuring SNMPConfiguring SNMPLimiting TFTP Servers Used Through S

Strany 406 - Displaying UDLD Status

25-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 25 Configuring SNMPDisplaying SNMP StatusThis example shows how to allo

Strany 407 - Configuring SPAN and RSPAN

CHAPTER 26-1Catalyst 2970 Switch Software Configuration Guide78-15462-0326Configuring Network Security with ACLsThis chapter describes how to configur

Strany 408 - Remote SPAN

26-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsUnderstanding ACLsYou configure

Strany 409 - SPAN Sessions

26-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsUnderstanding ACLsThe switch ex

Strany 410 - Monitored Traffic

26-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsUnderstanding ACLsYou can confi

Strany 411 - Source Ports

26-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring IP ACLsfirst ACE, e

Strany 412 - VLAN Filtering

1-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 1 OverviewWhere to Go NextLong-Distance, High-Bandwidth Transport Config

Strany 413 - Destination Port

26-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring IP ACLsCreating Sta

Strany 414 - RSPAN VLAN

26-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring IP ACLsNote In addi

Strany 415

26-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring IP ACLsNote When cr

Strany 416 - Configuring Local SPAN

26-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring IP ACLsSupported pa

Strany 417 - Creating a Local SPAN Session

26-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring IP ACLsor access-

Strany 418

26-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring IP ACLsUse the no

Strany 419

26-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring IP ACLsConsider th

Strany 420

26-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring IP ACLsTo remove a

Strany 421 - Specifying VLANs to Filter

26-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring IP ACLsRepeat the

Strany 422 - Configuring RSPAN

26-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring IP ACLsSwitch(conf

Strany 423

1-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 1 OverviewWhere to Go Next

Strany 424

26-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring IP ACLsApplying an

Strany 425

26-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring IP ACLsTo remove t

Strany 426

26-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring IP ACLsSwitch(conf

Strany 427

26-19Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring IP ACLsTime Range

Strany 428

26-20Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsCreating Named MAC Extended AC

Strany 429 - RSPAN sessions

26-21Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsCreating Named MAC Extended AC

Strany 430

26-22Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring VLAN MapsNote The

Strany 431 - Configuring RMON

26-23Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring VLAN MapsVLAN Map

Strany 432

26-24Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring VLAN MapsUse the n

Strany 433 - Default RMON Configuration

26-25Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring VLAN MapsSwitch(co

Strany 434

CHAPTER 2-1Catalyst 2970 Switch Software Configuration Guide78-15462-032Using the Command-Line InterfaceThis chapter describes the Cisco IOS command-l

Strany 435

26-26Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring VLAN MapsApplying

Strany 436 - Displaying RMON Status

26-27Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring VLAN MapsFigure 26

Strany 437

26-28Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsConfiguring VLAN MapsDenying A

Strany 438 - System Log Message Format

26-29Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsDisplaying ACL ConfigurationDi

Strany 439

26-30Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 26 Configuring Network Security with ACLsDisplaying ACL Configuration

Strany 440 - Disabling Message Logging

CHAPTER 27-1Catalyst 2970 Switch Software Configuration Guide78-15462-0327Configuring QoSThis chapter describes how to configure quality of service (Q

Strany 441 - Synchronizing Log Messages

27-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSThe classification is carried in the

Strany 442

27-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSAll switches and routers that access

Strany 443

27-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSActions at the egress interface inclu

Strany 444

27-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSYou specify which fields in the frame

Strany 445

ContentsvCatalyst 2970 Switch Software Configuration Guide78-15462-03Topology View 3-14CMS Icons 3-15Where to Go Next 3-15CHAPTER 4 Assigning the Swi

Strany 446

2-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 2 Using the Command-Line InterfaceUnderstanding Command ModesTable 2-1 de

Strany 447

27-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSFigure 27-3 Classification Flowchart8

Strany 448

27-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSClassification Based on QoS ACLs You

Strany 449 - Configuring SNMP

27-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSYou create and name a policy map by u

Strany 450 - SNMP Versions

27-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSPolicing uses a token-bucket algorith

Strany 451 - SNMP Manager Functions

27-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSMapping TablesDuring QoS processing,

Strany 452 - SNMP Agent Functions

27-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSQueueing and Scheduling OverviewThe

Strany 453 - SNMP Notifications

27-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSFigure 27-6 WTD and Queue OperationF

Strany 454

27-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSQueueing and Scheduling on Ingress Q

Strany 455 - SNMP Configuration Guidelines

27-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSYou assign each packet that flows th

Strany 456 - Configuring Community Strings

27-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSQueueing and Scheduling on Egress Qu

Strany 457

2-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 2 Using the Command-Line InterfaceUnderstanding the Help SystemUnderstand

Strany 458

27-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSFigure 27-9 shows the egress queue b

Strany 459

27-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSUnderstanding QoSthreshold-id cos1...cos8} global con

Strany 460

27-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Auto-QoS• Depending on the QoS label assi

Strany 461

27-19Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Auto-QoSTable 27-3 shows the generated au

Strany 462

27-20Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Auto-QoS• When you enter the auto qos voi

Strany 463 - SNMP Examples

27-21Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Auto-QoSThe switch automatically maps DSC

Strany 464 - Displaying SNMP Status

27-22Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Auto-QoSEffects of Auto-QoS on the Config

Strany 465 - Understanding ACLs

27-23Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Auto-QoSEnabling Auto-QoS for VoIPBeginni

Strany 466 - Supported ACLs

27-24Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Auto-QoSAuto-QoS Configuration ExampleThi

Strany 467 - VLAN Maps

27-25Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Auto-QoSNote You should not configure any

Strany 468 - Catalyst 2970 switch

2-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 2 Using the Command-Line InterfaceUnderstanding Abbreviated CommandsUnder

Strany 469 - Configuring IP ACLs

27-26Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSDisplaying Auto-QoS InformationDisplaying Auto-QoS In

Strany 470 - Access List Numbers

27-27Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSDefault Standard QoS Configur

Strany 471

27-28Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSDefault Egress Queue Configur

Strany 472

27-29Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSStandard QoS Configuration Gu

Strany 473

27-30Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSEnabling QoS GloballyBy defau

Strany 474

27-31Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSConfiguring the Trust State o

Strany 475

27-32Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSBeginning in privileged EXEC

Strany 476

27-33Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSConfiguring the CoS Value for

Strany 477 - Using Time Ranges with ACLs

27-34Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSConfiguring a Trusted Boundar

Strany 478

27-35Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSConfiguring the DSCP Trust St

Strany 479 - Including Comments in ACLs

2-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 2 Using the Command-Line InterfaceUnderstanding CLI Error MessagesUnderst

Strany 480

27-36Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSTo return a port to its non-t

Strany 481 - IP ACL Configuration Examples

27-37Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSClassifying Traffic by Using

Strany 482 - Named ACLs

27-38Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSBeginning in privileged EXEC

Strany 483 - Commented IP ACL Entries

27-39Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSBeginning in privileged EXEC

Strany 484

27-40Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSClassifying Traffic by Using

Strany 485

27-41Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSTo delete an existing class m

Strany 486 - Configuring VLAN Maps

27-42Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSClassifying, Policing, and Ma

Strany 487 - Creating a VLAN Map

27-43Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSStep 5trust [cos | dscp | ip-

Strany 488 - Example 2

27-44Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSTo delete an existing policy

Strany 489 - Example 4

27-45Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSSwitch(config-ext-mac)# exitS

Strany 490 - Applying a VLAN Map to a VLAN

2-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 2 Using the Command-Line InterfaceUsing Editing FeaturesBeginning in line

Strany 491

27-46Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSTo remove the specified aggre

Strany 492

27-47Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSSwitch(config)# interface gig

Strany 493 - Displaying ACL Configuration

27-48Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSThis example shows how to mod

Strany 494

27-49Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSConfiguring the Policed-DSCP

Strany 495 - Configuring QoS

27-50Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSConfiguring the DSCP-to-CoS M

Strany 496 - Understanding QoS

27-51Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSConfiguring the DSCP-to-DSCP-

Strany 497 - Basic QoS Model

27-52Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSThis example shows how to def

Strany 498 - Classification

27-53Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSMapping DSCP or CoS Values to

Strany 499

27-54Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSThis example shows how to map

Strany 500

27-55Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSAllocating Bandwidth Between

Strany 501

2-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 2 Using the Command-Line InterfaceUsing Editing FeaturesEnabling and Disa

Strany 502 - Policing and Marking

27-56Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSConfiguring the Ingress Prior

Strany 503

27-57Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSConfiguring Egress Queue Char

Strany 504 - Mapping Tables

27-58Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSAllocating Buffer Space to an

Strany 505 - Weighted Tail Drop

27-59Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSTo return to the default sett

Strany 506 - SRR Shaping and Sharing

27-60Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSMapping DSCP or CoS Values to

Strany 507

27-61Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSThis example shows how to map

Strany 508 - Priority Queueing

27-62Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSThis example shows how to con

Strany 509

27-63Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSConfiguring the Egress Expedi

Strany 510 - Buffer and Memory Allocation

27-64Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSConfiguring Standard QoSLimiting the Bandwidth on an

Strany 511 - Packet Modification

27-65Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSDisplaying Standard QoS InformationDisplaying Standar

Strany 512 - Configuring Auto-QoS

2-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 2 Using the Command-Line InterfaceUsing Editing FeaturesEditing Command L

Strany 513

27-66Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 27 Configuring QoSDisplaying Standard QoS Information

Strany 514

CHAPTER 28-1Catalyst 2970 Switch Software Configuration Guide78-15462-0328Configuring EtherChannelsThis chapter describes how to configure EtherChanne

Strany 515

28-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsUnderstanding EtherChannelsEtherChannel Over

Strany 516

28-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsUnderstanding EtherChannelsPort-Channel Inte

Strany 517 - Enabling Auto-QoS for VoIP

28-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsUnderstanding EtherChannelsadministrative, a

Strany 518

28-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsUnderstanding EtherChannelsUse the silent mo

Strany 519

28-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsUnderstanding EtherChannelsLACP ModesTable 2

Strany 520 - Configuring Standard QoS

28-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsUnderstanding EtherChannelsWith source-MAC a

Strany 521

28-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsConfiguring EtherChannelsFigure 28-3 Load Di

Strany 522

28-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsConfiguring EtherChannelsDefault EtherChanne

Strany 523

2-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 2 Using the Command-Line InterfaceSearching and Filtering Output of show

Strany 524 - Enabling QoS Globally

28-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsConfiguring EtherChannels• Do not configure

Strany 525

28-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsConfiguring EtherChannelsTo remove an inter

Strany 526

28-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsConfiguring EtherChannelsThis example shows

Strany 527

28-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsConfiguring EtherChannelsTo return EtherCha

Strany 528

28-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsConfiguring EtherChannelsTo return the prio

Strany 529

28-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsConfiguring EtherChannelsConfiguring LACP H

Strany 530 - Configuring a QoS Policy

28-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsConfiguring EtherChannelsTo return the LACP

Strany 531

28-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsDisplaying EtherChannel, PAgP, and LACP Sta

Strany 532

28-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 28 Configuring EtherChannelsDisplaying EtherChannel, PAgP, and LACP Sta

Strany 533

CHAPTER 29-1Catalyst 2970 Switch Software Configuration Guide78-15462-0329TroubleshootingThis chapter describes how to identify and resolve software p

Strany 534

2-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 2 Using the Command-Line InterfaceAccessing the CLIAccessing the CLIYou

Strany 535

29-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter29 TroubleshootingRecovering from Corrupted Software By Using the XMODEM

Strany 536

29-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 29 TroubleshootingRecovering from Corrupted Software By Using the XMODEM

Strany 537

29-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter29 TroubleshootingRecovering from a Lost or Forgotten PasswordRecovering

Strany 538

29-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 29 TroubleshootingRecovering from a Lost or Forgotten PasswordProcedure

Strany 539

29-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter29 TroubleshootingRecovering from a Lost or Forgotten PasswordStep 9 Copy

Strany 540

29-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 29 TroubleshootingRecovering from a Lost or Forgotten Password• If you e

Strany 541 - Configuring DSCP Maps

29-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter29 TroubleshootingRecovering from a Command Switch FailureStep 9 Write th

Strany 542

29-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 29 TroubleshootingRecovering from a Command Switch FailureStep 3 Start a

Strany 543

29-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter29 TroubleshootingRecovering from a Command Switch FailureStep 12 When p

Strany 544

29-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 29 TroubleshootingRecovering from Lost Cluster Member ConnectivityStep

Strany 545

2-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 2 Using the Command-Line InterfaceAccessing the CLINote Copies of the HT

Strany 546

29-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter29 TroubleshootingPreventing Autonegotiation MismatchesPreventing Autone

Strany 547

29-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 29 TroubleshootingUsing PingUsing PingThis section consists of this inf

Strany 548

29-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter29 TroubleshootingUsing Layer 2 TracerouteTo terminate a ping session, e

Strany 549

29-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 29 TroubleshootingUsing Layer 2 TracerouteNote For more information abo

Strany 550

29-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter29 TroubleshootingUsing IP TracerouteUsing IP TracerouteThis section con

Strany 551

29-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 29 TroubleshootingUsing Debug CommandsThis example shows how to perform

Strany 552

29-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter29 TroubleshootingUsing Debug CommandsNote For complete syntax and usage

Strany 553

29-19Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 29 TroubleshootingUsing the show platform forward CommandRedirecting De

Strany 554

29-20Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter29 TroubleshootingUsing the show platform forward Command Lookup

Strany 555

29-21Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 29 TroubleshootingUsing the crashinfo FileUsing the crashinfo FileThe c

Strany 556

ContentsviCatalyst 2970 Switch Software Configuration Guide78-15462-03Discovery Through Different VLANs 5-7Discovery Through Different Management VLA

Strany 557

2-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 2 Using the Command-Line InterfaceAccessing the CLI

Strany 558

29-22Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter29 TroubleshootingUsing the crashinfo File

Strany 559

A-1Catalyst 2970 Switch Software Configuration Guide78-15462-03APPENDIXASupported MIBsThis appendix lists the supported management information base (

Strany 560

A-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix A Supported MIBsMIB List• CISCO-PAGP-MIB• CISCO-PING-MIB• CISCO-PROCESS-

Strany 561 - Configuring EtherChannels

A-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix A Supported MIBsUsing FTP to Access the MIB FilesNote You can also use t

Strany 562 - EtherChannel Overview

A-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix A Supported MIBsUsing FTP to Access the MIB Files

Strany 563 - Port Aggregation Protocol

B-1Catalyst 2970 Switch Software Configuration Guide78-15462-03APPENDIXBWorking with the Cisco IOS File System, Configuration Files, and Software Ima

Strany 564 - PAgP Modes

B-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Softw

Strany 565 - Understanding EtherChannels

B-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Softw

Strany 566 - LACP Modes

B-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Softw

Strany 567

B-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Softw

Strany 568

CHAPTER 3-1Catalyst 2970 Switch Software Configuration Guide78-15462-033Getting Started with CMSThis chapter contains these sections that describe the

Strany 569

B-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Softw

Strany 570

B-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Softw

Strany 571

B-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Softw

Strany 572

B-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Softw

Strany 573

B-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 574

B-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 575

B-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 576

B-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 577

B-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 578

B-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 579 - Troubleshooting

3-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 3 Getting Started with CMSUnderstanding CMSFront Panel ViewThe Front Pane

Strany 580 - Protocol

B-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 581

B-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 582

B-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 583

B-19Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 584

B-20Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 585

B-21Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 586

B-22Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 587

B-23Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 588

B-24Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 589

B-25Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 590

3-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 3 Getting Started with CMSUnderstanding CMS• The feature bar shows the fe

Strany 591 - Using Ping

B-26Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 592 - Using Layer 2 Traceroute

B-27Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 593 - Displaying the Physical Path

B-28Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 594 - Using IP Traceroute

B-29Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 595 - Using Debug Commands

B-30Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 596

B-31Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 597

B-32Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 598

B-33Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 599 - Using the crashinfo File

B-34Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix B Working with the Cisco IOS File System, Configuration Files, and Soft

Strany 600

C-1Catalyst 2970 Switch Software Configuration Guide78-15462-03APPENDIXCUnsupported Commands in Cisco IOS Release 12.1(19)EA1This appendix lists some

Strany 601 - Supported MIBs

3-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 3 Getting Started with CMSUnderstanding CMSFigure 3-2 Feature Bar and Sea

Strany 602 - MIB List

C-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix C Unsupported Commands in Cisco IOS Release 12.1(19)EA1IGMP Snooping Com

Strany 603

C-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix C Unsupported Commands in Cisco IOS Release 12.1(19)EA1RADIUSUnsupported

Strany 604

C-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Appendix C Unsupported Commands in Cisco IOS Release 12.1(19)EA1VLANUnsupported I

Strany 605 - APPENDIX

IN-1Catalyst 2970 Switch Software Configuration Guide78-15462-03INDEXNumerics802.1DSee STP802.1Qand trunk ports9-3configuration limitations 11-17enca

Strany 606

IndexIN-2Catalyst 2970 Switch Software Configuration Guide78-15462-03IPapplying to interface26-16applying to interfaces 26-16creating 26-6fragments a

Strany 607

IndexIN-3Catalyst 2970 Switch Software Configuration Guide78-15462-03authenticationlocal mode with AAA7-36NTP associations 6-5RADIUSkey7-21login 7-23

Strany 608 - Copying Files

IndexIN-4Catalyst 2970 Switch Software Configuration Guide78-15462-03BPDU guarddescribed16-3enabling 16-11support for 1-5bridge protocol data unitSee

Strany 609 - Deleting Files

IndexIN-5Catalyst 2970 Switch Software Configuration Guide78-15462-03clusters, switchaccessing5-13adding member switches 5-16automatic discovery 5-5a

Strany 610 - Creating a tar File

IndexIN-6Catalyst 2970 Switch Software Configuration Guide78-15462-03replacingwith another switch29-10with cluster member 29-8requirements 5-3standby

Strany 611 - Extracting a tar File

IndexIN-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Ddaylight saving time 6-14debuggingenabling all system diagnostics29-18enabling

Strany 612

3-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 3 Getting Started with CMSUnderstanding CMSOnline help includes these fea

Strany 613

IndexIN-8Catalyst 2970 Switch Software Configuration Guide78-15462-03DHCP snoopingconfiguration guidelines17-3default configuration 17-3displaying bi

Strany 614

IndexIN-9Catalyst 2970 Switch Software Configuration Guide78-15462-03encryption for passwords 7-4environment variablesfunction of4-16error messages d

Strany 615

IndexIN-10Catalyst 2970 Switch Software Configuration Guide78-15462-03displaying the contents of 29-21location 29-21deleting B-5displaying the conten

Strany 616

IndexIN-11Catalyst 2970 Switch Software Configuration Guide78-15462-03HP OpenView 1-3HSRPautomatic cluster recovery5-12cluster standby group consider

Strany 617

IndexIN-12Catalyst 2970 Switch Software Configuration Guide78-15462-03descriptive name, adding 9-14displaying information about 9-16flow control 9-12

Strany 618

IndexIN-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Kerberosauthenticating toboundary switch7-35KDC 7-35network services 7-35config

Strany 619

IndexIN-14Catalyst 2970 Switch Software Configuration Guide78-15462-03characteristics of 6-26dropping 6-28removing 6-27MAC address notification, supp

Strany 620

IndexIN-15Catalyst 2970 Switch Software Configuration Guide78-15462-03IGMPfilters18-25snooping 18-12interfaces 9-16multicast router interfaces 18-12M

Strany 621

IndexIN-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Port Fastdescribed16-2enabling 16-10preventing root switch selection 16-7root g

Strany 622

IndexIN-17Catalyst 2970 Switch Software Configuration Guide78-15462-03overview 6-2restricting accesscreating an access group6-9disabling NTP services

Strany 623

3-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 3 Getting Started with CMSUnderstanding CMSGuide mode is not available if

Strany 624 - Working with Software Images

IndexIN-18Catalyst 2970 Switch Software Configuration Guide78-15462-03port-based authenticationauthentication serverdefined8-2RADIUS server 8-2client

Strany 625

IndexIN-19Catalyst 2970 Switch Software Configuration Guide78-15462-03protected 19-5secure 19-7static-access 11-3, 11-11switch 9-2trunks 11-3, 11-15V

Strany 626

IndexIN-20Catalyst 2970 Switch Software Configuration Guide78-15462-03policy maps, described 27-7trust DSCP, described 27-5trusted CoS, described 27-

Strany 627

IndexIN-21Catalyst 2970 Switch Software Configuration Guide78-15462-03marked-down actions 27-43marking, described 27-3, 27-8overview 27-1packet modif

Strany 628

IndexIN-22Catalyst 2970 Switch Software Configuration Guide78-15462-03RCPconfiguration filesdownloadingB-17overview B-16preparing the server B-16uplo

Strany 629

IndexIN-23Catalyst 2970 Switch Software Configuration Guide78-15462-03received traffic 22-4session limits 22-10sessionscreating22-17defined 22-3limit

Strany 630

IndexIN-24Catalyst 2970 Switch Software Configuration Guide78-15462-03shutdown command on interfaces 9-17Simple Network Management ProtocolSee SNMPSm

Strany 631

IndexIN-25Catalyst 2970 Switch Software Configuration Guide78-15462-03destination ports 22-7displaying status 22-23interaction with other features 22

Strany 632

IndexIN-26Catalyst 2970 Switch Software Configuration Guide78-15462-03sticky learning 19-8storm controlconfiguring19-3described 19-2displaying 19-15s

Strany 633

IndexIN-27Catalyst 2970 Switch Software Configuration Guide78-15462-03root guarddescribed16-7enabling 16-14root port, defined 14-3root switchconfigur

Strany 634

3-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 3 Getting Started with CMSConfiguring CMSAccess to Older Switches In a Cl

Strany 635

IndexIN-28Catalyst 2970 Switch Software Configuration Guide78-15462-03TTACACS+accounting, defined7-11authentication, defined 7-11authorization, defin

Strany 636

IndexIN-29Catalyst 2970 Switch Software Configuration Guide78-15462-03trafficblocking flooded19-6fragmented 26-4unfragmented 26-4traffic policing 1-7

Strany 637

IndexIN-30Catalyst 2970 Switch Software Configuration Guide78-15462-03and broadcast MAC addresses 6-27and CPU packets 6-27and multicast addresses 6-2

Strany 638

IndexIN-31Catalyst 2970 Switch Software Configuration Guide78-15462-03defined 26-2, 26-3denying access example 26-28denying and permitting packets 26

Strany 639 - Cisco IOS Release 12.1(19)EA1

IndexIN-32Catalyst 2970 Switch Software Configuration Guide78-15462-03connecting to an IP phone 13-4default configuration 13-3described 13-1displayin

Strany 640 - Interface Commands

3-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 3 Getting Started with CMSConfiguring CMSOperating System and Browser Sup

Strany 641 - Spanning Tree

3-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 3 Getting Started with CMSConfiguring CMSSolarisFor Solaris, Java plug-in

Strany 642 - Miscellaneous

ContentsviiCatalyst 2970 Switch Software Configuration Guide78-15462-03Configuring the Time Zone 6-13Configuring Summer Time (Daylight Saving Time)

Strany 643 - Numerics

3-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 3 Getting Started with CMSDisplaying CMSConfiguring an Authentication Me

Strany 644

3-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 3 Getting Started with CMSDisplaying CMSFigure 3-4 Switch Home PageThe S

Strany 645

3-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 3 Getting Started with CMSDisplaying CMSStep 3 Click Cluster Management

Strany 646

3-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 3 Getting Started with CMSDisplaying CMSFront Panel ViewWhen CMS is laun

Strany 647

3-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 3 Getting Started with CMSDisplaying CMSNote Figure 3-7 shows a cluster

Strany 648

3-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 3 Getting Started with CMSWhere to Go NextNote Figure 3-8 shows multiple

Strany 649

3-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 3 Getting Started with CMSWhere to Go Next

Strany 650

CHAPTER 4-1Catalyst 2970 Switch Software Configuration Guide78-15462-034Assigning the Switch IP Address and Default GatewayThis chapter describes how

Strany 651

4-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayAssigning Switch Inf

Strany 652

4-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayAssigning Switch Inf

Strany 653

ContentsviiiCatalyst 2970 Switch Software Configuration Guide78-15462-03Controlling Switch Access with TACACS+ 7-10Understanding TACACS+ 7-10TACACS+

Strany 654

4-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayAssigning Switch Inf

Strany 655

4-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayAssigning Switch Inf

Strany 656

4-6Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayAssigning Switch Inf

Strany 657

4-7Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayAssigning Switch Inf

Strany 658

4-8Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayAssigning Switch Inf

Strany 659

4-9Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayAssigning Switch Inf

Strany 660

4-10Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayAssigning Switch In

Strany 661

4-11Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayChecking and Saving

Strany 662

4-12Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayModifying the Start

Strany 663

4-13Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayModifying the Start

Strany 664

ContentsixCatalyst 2970 Switch Software Configuration Guide78-15462-03Configuring SSH 7-39Configuration Guidelines 7-39Setting Up the Switch to Run S

Strany 665

4-14Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayModifying the Start

Strany 666

4-15Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayModifying the Start

Strany 667

4-16Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayModifying the Start

Strany 668

4-17Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayScheduling a Reload

Strany 669

4-18Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 4 Assigning the Switch IP Address and Default GatewayScheduling a Reload

Strany 670

CHAPTER 5-1Catalyst 2970 Switch Software Configuration Guide78-15462-035Clustering SwitchesThis chapter provides the concepts and procedures to create

Strany 671

5-2Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesUnderstanding Switch ClustersUnderstanding Switch Cl

Strany 672

5-3Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesUnderstanding Switch ClustersCluster Command Switch

Strany 673

5-4Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesPlanning a Switch ClusterCandidate Switch and Cluste

Strany 674

5-5Catalyst 2970 Switch Software Configuration Guide78-15462-03Chapter 5 Clustering SwitchesPlanning a Switch ClusterAutomatic Discovery of Clus

Komentáře k této Příručce

Žádné komentáře