Strany 1 - Blade Server

CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.20 NOVEMBER 25, 2013 WWW.CISCO.COMSpec SheetCisco UCS B200 M3Blade Se

Strany 2

Cisco UCS B200 M3 Blade Server10CONFIGURING the SERVERSupported Configurations(1) One-CPU Configuration Choose one CPU from any one of the rows of Ta

Strany 3 - OVERVIEW

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER11— The connectivity options are:• VIC 1240 installed in VIC 1240 slot and no adapter installed in

Strany 4 - DETAILED VIEWS

Cisco UCS B200 M3 Blade Server12CONFIGURING the SERVERSTEP 3 CHOOSE MEMORYThe standard memory features are: DIMMs— Clock speed: 1866, 1600, or 1333 M

Strany 5

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER13Choose DIMMs and Memory MirroringSelect the memory configuration and whether or not you want the

Strany 6

Cisco UCS B200 M3 Blade Server14CONFIGURING the SERVERSupported Configurations(1) B200 M3 configured with 1 CPU without memory mirroring Select from

Strany 7

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER15(3) B200 M3 configured with 2 CPUs without memory mirroring: Select from 1 to 12 DIMMs per CPU

Strany 8 - STEP 1 VERIFY SERVER SKU

Cisco UCS B200 M3 Blade Server16CONFIGURING the SERVERCaveats System speed is dependent on how many DIMMs are populated per channel. See Table 7 for

Strany 9 - STEP 2 CHOOSE CPU(S)

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER17— BIOS setting. For the DIMMs to run in power-savings mode (1.35 V, if the DIMM supports this),

Strany 10 - Notes

Cisco UCS B200 M3 Blade Server18CONFIGURING the SERVERSTEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES (OPTIONAL)The UCS B200 M3 can be ordered wi

Strany 11

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER19Supported Configurations(1) 1-Drive System Select one of the drives listed in Table 8. (1) 2-Dr

Strany 12 - STEP 3 CHOOSE MEMORY

Cisco UCS B200 M3 Blade Server2OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3DETAILED VIEWS

Strany 13

Cisco UCS B200 M3 Blade Server20CONFIGURING the SERVERSTEP 5 CHOOSE ADAPTERSThe adapter offerings are: Cisco Virtual Interface Cards (VICs)Cisco deve

Strany 14

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER21Supported Configurations(1) B200 M3 configured with 1 CPUFor a B200 M3 configured with 1 CPU, th

Strany 15

Cisco UCS B200 M3 Blade Server22CONFIGURING the SERVER(2) B200 M3 configured with 2 CPUsFor a B200 M3 configured with 2 CPUs, the supported configurat

Strany 16

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER23STEP 6 ORDER A TRUSTED PLATFORM MODULETrusted Platform Module (TPM) is a computer chip (microcon

Strany 17

Cisco UCS B200 M3 Blade Server24CONFIGURING the SERVERSTEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDSDual SDHC flash card sockets are provided

Strany 18

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER25STEP 8 ORDER OPTIONAL INTERNAL USB 2.0 DRIVEYou may order one optional internal USB 2.0 drive. T

Strany 19

Cisco UCS B200 M3 Blade Server26CONFIGURING the SERVERSTEP 9 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARESeveral operating systems and value-added

Strany 20 - STEP 5 CHOOSE ADAPTERS

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER27Red Hat Enterprise LinuxRHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs RequiredRHEL-2S-1G-3A RHEL/

Strany 21 - CONFIGURING the SERVER

Cisco UCS B200 M3 Blade Server28CONFIGURING the SERVERVMware 5VMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support RqdVMW-VS5-STD

Strany 22

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER29STEP 10 CHOOSE OPERATING SYSTEM MEDIA KITChoose the optional operating system media listed in Ta

Strany 23

Cisco UCS B200 M3 Blade ServerOVERVIEW3OVERVIEWDelivering performance, versatility and density without compromise, the Cisco UCS B200 M3 Blade Server

Strany 24

Cisco UCS B200 M3 Blade Server30CONFIGURING the SERVERSTEP 11 CHOOSE SERVICE and SUPPORT LEVELA variety of service options are available, as described

Strany 25

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER31Unified Computing Warranty Plus ServiceFor faster parts replacement than is provided with the st

Strany 26

Cisco UCS B200 M3 Blade Server32CONFIGURING the SERVERPartner Support Service for UCS provides hardware and software support, including triage support

Strany 27

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER33You can choose a service listed in Table 21.Unified Computing Drive Retention ServiceWith the Ci

Strany 28

Cisco UCS B200 M3 Blade Server34CONFIGURING the SERVERFor more service and support information, see the following URL:http://www.cisco.com/en/US/servi

Strany 29

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER35ORDER OPTIONAL KVM LOCAL I/O CABLE*The KVM local I/O cable ships with every UCS 5100 Series blad

Strany 30

Cisco UCS B200 M3 Blade Server36SUPPLEMENTAL MATERIALSUPPLEMENTAL MATERIALSystem BoardA top view of the UCS B200 M3 system board is shown in Figure 5.

Strany 31

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL37CPUs and DIMMsPhysical LayoutMemory is organized as shown in Figure 6.Figure 6 UCS B200 M3 Memo

Strany 32

Cisco UCS B200 M3 Blade Server38SUPPLEMENTAL MATERIAL— Bank 1 - E1, F1, G1, and H1 (black DIMM slots)— Bank 2 - E2, F2, G2, and H2 (white DIMM slots)T

Strany 33

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL39DIMM Population Rules When considering the memory configuration of your server, you should take i

Strany 34

Cisco UCS B200 M3 Blade Server4DETAILED VIEWSDETAILED VIEWSBlade Server Front ViewFigure 2 is a detailed front view of the Cisco UCS B200 M3 Blade Ser

Strany 35

Cisco UCS B200 M3 Blade Server40SUPPLEMENTAL MATERIALDIMM Population OrderPopulate the DIMMs for a CPU according to Table 25.Table 25 DIMM Populatio

Strany 36 - SUPPLEMENTAL MATERIAL

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL41Upgrade and Servicing-Related PartsThis section lists the upgrade and servicing-related parts you

Strany 37 - CPUs and DIMMs

Cisco UCS B200 M3 Blade Server42SUPPLEMENTAL MATERIALAdding an Additional CPU (with CPU heat sink)All Cisco UCS two CPU socket-capable servers can be

Strany 38

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL43Air Baffle Replacement KitAir baffles are designed to direct airflow through the server to mainta

Strany 39 - DIMM Population Rules

Cisco UCS B200 M3 Blade Server44SUPPLEMENTAL MATERIALNetwork ConnectivityThis section explains how the UCS B200 M3 server connects to Fabric Interconn

Strany 40 - DIMM Population Order

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL45The network adapter options are: Cisco VIC 1240 adapter. This adapter plugs into the VIC 1240 sl

Strany 41

Cisco UCS B200 M3 Blade Server46SUPPLEMENTAL MATERIALFigure 9 VIC 1240 Port ConnectivityThe number of ports available at the mezzanine adapter depen

Strany 42 - Motherboard Lithium Battery

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL47— QLogic M73KR-Q Cisco Storage Accelerator adapters— Cisco UCS 785 GB MLC Fusion-io ioDrive2— LS

Strany 43 - CPU Heat Sink Cleaning Kit

Cisco UCS B200 M3 Blade Server48SUPPLEMENTAL MATERIALIn Figure 11, two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are c

Strany 44 - Network Connectivity

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL49Figure 12 Option 1 - VIC 1240 to UCS 2204XP Fabric Extender (no mezzanine adapter)In Figure 13,

Strany 45 - VIC 1240 Adapter

Cisco UCS B200 M3 Blade ServerBASE SERVER STANDARD CAPABILITIES and FEATURES5BASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 lists the capabilit

Strany 46 - Mezzanine Adapters

Cisco UCS B200 M3 Blade Server50SUPPLEMENTAL MATERIALConnectivity using the Cisco UCS 2104XP Fabric ExtenderThe option shown in Figure 14 demonstrates

Strany 47 - B200 M3 Configured with 1 CPU

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL51B200 M3 Configured with 2 CPUsConnectivity using the Cisco UCS 2208XP Fabric ExtenderThe Cisco UC

Strany 48 - ■ VIC 1240 to 2204XP

Cisco UCS B200 M3 Blade Server52SUPPLEMENTAL MATERIALIn Figure 16, two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are c

Strany 49

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL53In Figure 18, two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are c

Strany 50 - Fabric Extender

Cisco UCS B200 M3 Blade Server54SUPPLEMENTAL MATERIALConnectivity using the Cisco UCS 2204XP Fabric ExtenderThe Cisco UCS 2204XP is a second-generatio

Strany 51

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL55In Figure 21, one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is chan

Strany 52

Cisco UCS B200 M3 Blade Server56SUPPLEMENTAL MATERIALIn Figure 23, one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is chan

Strany 53

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL57Connectivity using the Cisco UCS 2104XP Fabric ExtenderThe options shown in Figure 25 and Figure

Strany 54

Cisco UCS B200 M3 Blade Server58TECHNICAL SPECIFICATIONSTECHNICAL SPECIFICATIONSDimensions and WeightPower SpecificationsFor configuration-specific po

Strany 55

Cisco UCS B200 M3 Blade Server6BASE SERVER STANDARD CAPABILITIES and FEATURESVideo The Cisco Integrated Management Controller (CIMC) provides video:

Strany 56

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER7CONFIGURING the SERVERFollow these steps to configure the Cisco UCS B200 M3 Blade Server: STEP 1

Strany 57

Cisco UCS B200 M3 Blade Server8CONFIGURING the SERVERSTEP 1 VERIFY SERVER SKUVerify the product ID (PID) of the server as shown in Table 2.The base Ci

Strany 58 - TECHNICAL SPECIFICATIONS

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER9STEP 2 CHOOSE CPU(S)The standard CPU features are: Intel Xeon E5-2600 v2 and E5-2600 series proc