Quick Start Guide
1 Documentation and Resources 2
2 Prepare for Installation 4
3 Rack-Mount the SCE 1000 7
4 Connect the Power Supply Units 13
5 Connect the Management Interfaces and Perform Initial System Configuration 18
6 Cable the Line Ports 43
7 Completing the Installation 47
8 Troubleshoot Startup Problems 54
9 Obtain Technical Assistance 57
Cisco SCE 1000 2xGBE Quick Start Guide
Version 2.5.7
OL-7822-02
Zobrazit stránku 0
1 2 3 4 5 6 ... 57 58

Shrnutí obsahu

Strany 1 - Quick Start Guide

Quick Start Guide 1 Documentation and Resources 2 2 Prepare for Installation 4 3 Rack-Mount the SCE 1000 7 4 Connect the Power Supply Un

Strany 2 - Documentation and Resources

10 Attach the Crossrail Supports to the Rack Figure 5: Attaching the Crossrails to the Rack Step 1 Align the crossrail supports with the side of

Strany 3 - Documentation Feedback

11 Mount the System to the Rack When the appropriate mounting brackets are securely installed, the SCE 1000 can be installed into the rack. Figur

Strany 4 - 2 Prepare for Installation

12 Step 4 While keeping the brackets flush against the posts or mounting strips, align the holes in the brackets with the holes on the rack or moun

Strany 5 - Tools and Parts

13 4 Connect the Power Supply Units This section provides information for grounding the SCE 1000 platform and connecting the AC or DC power suppl

Strany 6

14 Figure 9: Grounding the Unit (DC) A Grounding kit is provided with each SCE 1000. Use this Grounding kit to properly ground the SCE 1000 chassi

Strany 7 - 3 Rack-Mount the SCE 1000

15 Connect the Power The following sections describe how to reconnect the AC or DC power: • Connect the DC-Input Power Supply Unit (on page 15) •

Strany 8

16 Step 1 Ensure that the DC power line input leads are disconnected from the power source. Step 2 Using the number 2 Phillips screwdriver, remo

Strany 9

17 Connect the AC-Input Power Supply Unit Figure 11: Connecting the AC Power Step 1 Plug the AC-input power cable into the AC-input power recep

Strany 10

18 5 Connect the Management Interfaces and Perform Initial System Configuration This section explains how to connect the SCE 1000 platform to a loc

Strany 11 - Mount the System to the Rack

19 The above SCE 1000 port parameters are fixed and are not configurable. Step 1 Plug the RS-232 serial cable provided with the SCE 1000 into th

Strany 12

2 1 Documentation and Resources Documentation for the SCE 1000 platform is online and orderable. For detailed hardware installation instructions, r

Strany 13 - Connect the Chassis Ground

20 Setup Command Parameters Table 5-1 Setup Command Parameters Parameter Definition IP address IP address of the SCE 1000. subnet mask Subnet mas

Strany 14

21 Parameter Definition Access Control List number How many ACLs will be necessary? What IP addresses will be permitted/denied access for each ma

Strany 15 - Connect the Power

22 Following are some general instructions regarding the setup dialog: • All default values appear in square brackets [default]. If no value appear

Strany 16

23 • To accept the displayed value, press Enter. • To change the value, type the desired value in the format “x.x.x.x” and press Enter. EXAMPLE

Strany 17

24 • May contain only printable characters Note Passwords are case sensitive. Note The default password for all levels is “cisco”. To change th

Strany 18 - Configuration

25 You must enter the time setting menu in order to configure SNTP settings. You may choose to skip the time settings menu if you wish to accept a

Strany 19 - Initial System Configuration

26 • To change the value, type the desired number of seconds (64 through 1024) and press Enter. Enter time interval in seconds between unicast upda

Strany 20 - Setup Command Parameters

27 Note that there is no default domain name. You may accept the default domain name or enter a new one. Enter default domain name []: Step 4 Typ

Strany 21

28 Step 3 Type the TCP port number of the RDR-formatter destination and press Enter. Note that there is no default for this parameter. Enter RDR-fo

Strany 22 - XAMPLE:

29 • Individual IP address: Type the desired IP address, then enter the wildcard bits 0.0.0.0. Each individual IP address can be configured to be

Strany 23

3 Documentation Feedback You can send comments about technical documentation to this URL (http://[email protected]). You can submit comments b

Strany 24

30 Step 4 Begin adding entries to the selected list. Indicate whether this entry is permitted access or denied access. • To permit access, press E

Strany 25

31 To accept the default ACL, press Enter. Enter Telnet access-class [0]: 2 EXAMPLE: This example illustrates a common access control scenario. L

Strany 26

32 Step 8: Configuring SNMP Managing the SCE 1000 is possible also via a Network Management System (NMS) that supports SNMP. By default, SNMP is dis

Strany 27

33 Enter SNMP SET community name: Note that there is no default for this parameter. Step 7 Assign an access list to restrict the SNMP management s

Strany 28 - Entry Formats

34 • To disable the SCE enterprise traps, type n press Enter. • To enable the SCE enterprise traps, type y and press Enter. Enable the SCE enterpr

Strany 29 - Order of Entries

35 • Cascade: two cascaded SCE 1000s are deployed on two SCAS BB Console links, working as a fully redundant solution. • Physically connected li

Strany 30

36 • To define receive-only connection mode, type 2 and press Enter. Enter Connection mode: 1- inline 2- receive-only Enter your choice [1]: Step 3

Strany 31

37 The following examples present the procedure for configuring the topology-related parameters for various topologies. EXAMPLE #1: Following is a

Strany 32 - Step 8: Configuring SNMP

38 EXAMPLE #3: Following is a sample topology configuration for a secondary SCE 1000 in a redundant inline topology. In this topology there are two

Strany 33

39 Found errors in the new configuration, would you like to view them? [yes]: The following errors were found: Warning - RDR formatter destinatio

Strany 34

4 2 Prepare for Installation This section contains warnings, information about tools and parts, site preparation information, and information for w

Strany 35 - Type y and press Enter

40 This completes the procedures for initial configuration of the SCE 1000 platform. EXAMPLE #1: Following is an example of a configuration that the

Strany 36

41 Connect the Management Interface Figure 13: Cabling the Management Port Note By default, the management port is configured to auto-negotiati

Strany 37

42 EXAMPLE: The following example displays a typical ping response where the target IP address is 10.1.1.201. C:\>ping 10.1.1.201 pinging 10.1.1.

Strany 38

43 6 Cable the Line Ports This chapter provides instructions for cabling the Gigabit Ethernet ports and for configuring Gigabit Ethernet (GBE) in

Strany 39

44 Single Link: Receive-only Topology In this topology, an external optical splitter resides physically on the GBE link between the subscriber side

Strany 40

45 Step 1 To enter the Global Configuration Mode, at the SCE 1000# prompt, type configure, and press Enter. The SCE 1000(config)# prompt appear

Strany 41

46 Refer to Cabling Diagrams (on page 43) to find the appropriate cabling diagram for the topology of your system for the specific connections requi

Strany 42 - EXAMPLE:

47 7 Completing the Installation This section discusses how to verify link connectivity and how to install a Service Control application. Examin

Strany 43 - 6 Cable the Line Ports

48 Viewing the User Log Counters View the user log for errors that occurred during the installation process. To display the user log device counters

Strany 44

49 To view the running configuration, complete the following steps: Step 1 At the SCE 1000# prompt, type show running-config. The system shows

Strany 45

5 Table 2-1 SCE Platform Model Information Model number SCE 1010 2xGBE Link Type Gigabit Ethernet Number of Ports 2 Number of Links 1 Site Pr

Strany 46

50 To show the version information for the SCE 1000 software and hardware, complete the following steps: Step 1 At the SCE 1000# prompt, type show

Strany 47 - Completing the Installation

51 To show the system uptime for the SCE 1000 software and hardware, complete the following steps: Step 1 At the SCE 1000# prompt, type show sys

Strany 48 - Viewing Configuration

52 EXAMPLE: The following example shows the running configuration file. SCE 1000#show running-config #This is a general configuration file (running-

Strany 49

53 Loading and Activating a Service Control Application The SCE 1000 platform provides the basic functionalities of Service Control analysis and e

Strany 50

54 8 Troubleshoot Startup Problems SCE 1000 Operational Status The following table lists the operational states of the SCE 1000. The Status LED on

Strany 51 - SCE 1000#

55 Identifying Startup Problems Startup problems are commonly due to the source power or to a poor cable connection. When you start up the SCE 10

Strany 52

56 • show interface FastEthernet 0/0: Displays IP address and auto-negotiation information for the management interface. Following is a sample outp

Strany 53

57 In total octets: 191520 In good unicast packets: 560 In good multicast packets: 0 In good broadcast packets: 0 In packets discarded: 0 In packe

Strany 54 - SCE 1000 Operational Status

58 Definitions of Service Request Severity To ensure that all cases are reported in a standard format, Cisco has established severity definitions. S

Strany 55 - Identifying Startup Problems

6 Workbench or Tabletop Installation Figure 1: Installing the System on a Flat Surface For a workbench or tabletop installation, verify the followi

Strany 56

7 3 Rack-Mount the SCE 1000 This section provides information for rack-mounting the SCE 1000 platform. There are two standard types of equipment

Strany 57 - Obtain Technical Assistance

8 Attach the Brackets to the SCE 1000 Before installing the SCE 1000 in the rack, you must first install an appropriate rack-mount bracket on each s

Strany 58

9 To install the rack-mount brackets on the SCE 1000 chassis, complete the following steps: Before installing the SCE 1000 in the rack, you must f