Data Sheet
© 2010 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 14 of 20
PoE Power Consumption
100 Percent Throughput Switch Power Consumption (no PoE loads)
The numbers indicate the power consumed by a typical switch under normal conditions. Normal conditions signify a
temperature of 25 degrees Celsius, atmospheric pressure in the range of 860 to 1060 mbar, and relative humidity
from 30 to 75 percent. Typically such power draws are only seen when encountering a 100 percent traffic load made
up entirely of 64-byte packets with no PoE loads on the switch and uplinks.
Measured 5 Percent Throughput Switch Power Consumption (no PoE loads)
The numbers indicate the power consumed by a typical switch under normal conditions. Normal conditions signify a
temperature of 25 degrees Celsius, atmospheric pressure in the range of 860 to 1060 mbar and relative humidity
from 30 to 75 percent. The numbers below indicate a 5 percent traffic load on the switch and its uplinks
100 Percent Throughput Switch Power Consumption (with maximum PoE loads)
The numbers indicate the power consumed by a typical system (the switch and the corresponding PoE loads) under
normal conditions. Normal conditions signify a temperature of 25 degrees Celsius, atmospheric pressure in the
range of 860 to 1060 mbar and relative humidity from 30 to 75 percent. Typically this power draw is realized when a
switch is running 100 percent traffic load of 64 byte sized packets on all its ports and uplinks and also drawing 100
percent PoE load .
5 Percent Throughput Switch Power Consumption (with 50 percent PoE loads).
The numbers indicate the power consumed by a typical system (the switch and the corresponding PoE loads) under
normal conditions. Normal conditions signify a temperature of 25 degrees Celsius, atmospheric pressure in the
range of 860 to 1060 mbar and relative humidity from 30 to 75 percent. The numbers below indicate a 5 percent
traffic load and 50 percent PoE load on the switch and its uplinks.
Table 6 lists the specifications of all the power supplies supported in Cisco Catalyst 3750-E Series Switches.
Table 6. Power Supply Specifications
Product Specifications Power Supply
C3K-PWR-1150WAC C3K-PWR-750WAC C3K-PWR-265WAC C3K-PWR-265WDC
Physical Specifications (H x W x D): 1.65 X 6.0 X
14.90 in
Weight: 5.6 lb (2.6 kg)
(H x W x D): 1.65 X 6.0 X
11.4 in
Weight: 3.9 lb (1.8 kg)
(H x W x D): 1.65 X 6.0 X
11.4 in
Weight: 3.3 lb (1.5 kg)
(H x W x D): 1.65 X 6.0 X
11.4 in
Weight: 3.5 lb (1.6 kg)
Operating Temperature 23 to 113°F (–5 to 4C)
Storage Temperature –40 to 15F (–40 to 7C)
Relative Humidity Operating,
Noncondensing
10 to 85% noncondensing
Relative Humidity Nonoperating,
Noncondensing
0 to 95% noncondensing
Altitude 10,000 ft. (3000 meters), up to 45°C
MTBF Calculated MTBF must be greater than 300,000 using Telcordia SR-332, Method 1, Case 3. Demonstrated
MTBF is 500,000 hr (with 90% confidence level).
EMI and EMC Compliance
FCC Part 15 (CFR 47) Class A
ICES-003 Class A
EN 55022 Class A
CISPR 22 Class A
AS/NZS 3548 Class A
VCCI Class A
EN 55024
EN300 386
EN 50082-1
EN 61000-3-2
EN 61000-3-3