System Description
System Description
The following sections describe the VPN 3002 hardware.
Physical Site Requirements
The VPN 3002 requires a normal computing-equipment environment, including
power requirements. For maximum protection, we recommend connecting it to a
conditioned power source or UPS (uninterruptible power supply). Be sure that the
power source provides a reliable Earth ground.
Physical Specifications
Width: 8.85 inches (22.48 cm)
Depth: 7 inches (17.78 cm)
Height: 2.12 inches (5.38 cm)
Weight: 2.25 lb. (1.02 kg)
External power supply:
Input: 100 to 240 VAC at 50/60 Hz (autosensing)
Output: 3.3 v @ 4 amps
Cooling: Normal operating environment, 32
o
to 122
o
F (0
o
to 50
o
C),
convection only; cooling intake vents are on the sides and top. Allow at least
3 inches (75 mm) of unobstructed space on all sides.
Cabling distances from an active network device: approximately 328 feet
(100 meters)
UL approved: electrical, mechanical, and construction
FCC, E.U., and VCCI Class B compliance