Command Types INIT-SYS
Reboots the system.
Syntax Description
INIT-SYS:[<tid>]:<aid>:<ctag>::<ph>;
LPOUTCHGD “Loss of Output Power Setpoint Changed”
(cerent15216EdfaLpoutSetpoint).
LPOUTDEVCHGD “Lpout (loss of output power) Deviation Changed”
(cerent15216EdfaLpoutDeviation).
LPOUTHYSTCHGD “Lpout (loss of output power) Hysteresis Changed”
(cerent15216EdfaLpoutHysteresis).
MAXCTMPCHGD “Max Case Temperature Changed
(cerent15216EdfaCtmpMax).
MAXCTMPHYSTCHGD “Max Ctmp (case temperature) Hysteresis Changed”
(cerent15216EdfaCtmpMaxHysteresis).
MINCTMPCHGD “Min Case Temperature Changed
(cerent15216EdfaCtmpMin).
MINCTMPHYSTCHGD “Min Ctmp (case temperature) Hysteresis Changed”
(cerent15216EdfaCtmpMinHysteresis).
PREATTCHGD “Pre-attenuation Changed”
(cerent15216EdfaVariableGainPreAttenuation).
PWRBUSMAXCHGD “Power Bus Max (voltage) Changed”
(cerent15216EdfaPowerBusDCVoltageMax).
PWRBUSMINCHGD “Power Bus Min (voltage) Changed”
(cerent15216EdfaPowerBusDCVoltageMin).
PWRBUSMODE “Power Bus Mode Changed”
(cerent15216EdfaPowerBusMode).
SEVERITYCHGD “Severity Changed from CR|MJ|MN|NA|NR to
CR|MJ|MN|NA|NR”.
SFTWDOWNERR “Software Load Error”.
SOFTWARERESET “Software Reset” (cerent15216EdfaOpReset).
SOFTWARERESETERR “Software Reset Error”
(cerent15216EdfaActionOpResult).
ALL Any or all of the preceding (command input only).
NULL Defaults to ALL.
Table 9-22 INH-MSG-ALL Syntax Description (continued)